Operation
11
You only have to adapt your ECU software and the ASAM-2MC description file
if you want to work with a larger number of variables in the current rate or
with more rates. If you want to work at rates of 100 MBit/sec., further changes
have to be made to the ASAM-2MC description file.
Details on the individual changes that have to be made can be found in the
description of the ETK interface which you can receive from ETAS on request.
The following table shows the performance characteristics of the individual
operating modes for the ETK interface.
CAN
In addition to CAN Monitoring, the CAN interfaces of the ES590 support cali-
bration via the CAN Calibration Protocol (CCP) and conversion from KWP2000
to CAN via Keyword-on-CAN.
K-Line
Calibration using the KWP2000 Keyword protocol and McMess are supported
on the K-Line of the ES590.
SMB
The serial interface of the ES590 can be used to connect one or several mea-
suring devices via a serial measuring bus.
Host
The connection to the host PC is established at the host interface. The connec-
tion can take place directly via the Ethernet board or with an ES600 when
using several Ethernet devices.
2.3
Assembly
The ES590 module has a robust metal housing with non-skid plastic feet. The
device can easily be screwed to a rack to position it in the vehicle or in the lab.
Operating Mode
Transfer
MBit/sec.
Rates
Variables
Standard mode
Individ.
8
3
29/45/45
Block
8, 100
3
29/45/45
Compatibility mode
Block
8, 100
3
100/100/100
Block
8, 100
8
Configurable
Extended mode
Block
100
16
Configurable