![eta EEP 130 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/eta/eep-130/eep-130_operating-instructions-manual_2430374015.webp)
Installation
Installing flue gas recirculation
15
Connect the horizontal flue pipe with the flue pipe
already installed. Add a seal and only hand-tighten the
screws.
Fig. 5-7: Horizontal flue pipe
Fasten the horizontal line onto the flue gas connection
with a seal.
Evenly tighten all screws on the flue pipe and the
pipe clamp. If tensions are apparent, loosen the
screws and align the components with one another.
Put the insulation over the flue pipe and seal the piles
with aluminium adhesive tape.
Block the flue gas recirculation
The piping must be closed if the flue gas recirculation
is not needed. The required shut-off device is included
in the delivery scope.
Fig. 5-8: Flue gas recirculation shut-off device