ETAtouch controller
[Aux.boiler] function block
71
5.9.1
Setting the charging times
Open the overview screen of the standby time
settings
The standby times of the burner can be adjusted in the
settings (
button). To adjust, open the settings and
then open the standby times of any given day with the
[Stand-by times Daily plan] button. An overview
screen opens.
Fig. 5-80: Overview
1
Set time windows (standby times)
2
Select day of the week
3
Add another time window
4
Graphical representation of the time window
setting
5
Overview of all time windows for the entire week
6
Delete time window
7
Period of the time window
Setting the time window and copying to other
days of the week is described in chapter
5.9.2
Text menu - Adjustable parameters
Adjustable parameters
Detailed descriptions of the parameters are provided
below.
Explanation of [Start lag]
This parameter is used to set the duration of a delay in
the operation of the auxiliary boiler after the ETA
control system has demanded it.
If there is still a demand by the ETA control system
after this period ends, then the auxiliary boiler will
begin operation.
Aux.boiler
Settings
Start lag
Содержание 13180LP-T
Страница 1: ...2018 05 24 EN 0000000313 V 005 3 43 0 3308 93222 001 Pellet boiler 180 220 kW Operation ...
Страница 29: ...ETAtouch controller Getting to know the control system 29 ...
Страница 39: ...ETAtouch controller BufferFlex function block 39 ...
Страница 47: ...ETAtouch controller Buffer function block 47 ...
Страница 51: ...ETAtouch controller Hot water tank function block 51 ...
Страница 55: ...ETAtouch controller Fresh water module function block 55 ...
Страница 69: ...ETAtouch controller Solar function block 69 ...
Страница 87: ......
Страница 88: ...www eta co at www eta co at downloads DOWNLOAD ...