to  ensure undisrupted electrical energy output from  the  array.  The hex nut in the exit 

position on the junction box is used to hold a rubber ring to seal the box. 

 

When disconnecting the connectors of a photovoltaic module in a module array that is 

exposed to sunlight, electric arcs may result. Such arcs may cause burns and fires. 

Therefore, PV system commissioning and maintenance must be performed by a qualified 

electrician in accordance with the NEC.  Before disconnecting a module in a solar array, 

disconnect the string of module from the DC Disconnect at the inverter side, and then 

fully cover the module with an opaque material. 

Do not short the positive and the 

negative connectors of a module exposed to sunlight. 

 

 

 

 

The specification of wire for the electric coupler that ET Solar provided is 1 x 4.0mm

2

Equivalent wire should be used if the user prefers to use his  own wire. When the 

module’s rated current is lower, 12AWG wire is recommended for use, and the strength 

of  the  wire should be taken into  consideration.  ET  Solar does not provide any output 

wiring for module installation.  

 

ET Solar modules are designed to use copper wire only. The working temperature of wire 

and J-box is –40

- 90

. The wiring box interior is not intended for field access, and no 

serviceable parts are inside.  

 

The installation in Canada shall be in accordance with CSA C22.1, Safety standard for 

electrical installations, Canadian Electrical Code, Part 1. 

 

3.3 Output Voltage, Current and Maximum Power 

The open-circuit voltage (Voc), short-circuit current (Isc) and maximal power (Pmax) are 

printed on the PET label on the backside of the module. The electrical characteristics are 

within ±10 percent of the indicated  values of Isc, Voc and Pmax under standard test 

WARNING! 

Wiring must only be completed by a qualified engineer with 
suitable tools. 

Содержание ET-P654180

Страница 1: ...solar PV projects around the world 2 Structure of module ET modules are made by layering low iron tempered glass an EVA sticky membrane high conversion efficient solar cells and a behind the membrane...

Страница 2: ...nded that the modules usually face the equator thus in the Northern Hemisphere the surface should be oriented towards the south and in the Southern Hemisphere towards the north Usually the angle betwe...

Страница 3: ...ion The surface of the modules should avoid shadows and be kept clean from foreign materials such as dirt The assembly is to be mounted over a fire resistant roof covering material when roof mounting...

Страница 4: ...s will use the four inner mounting holes on the module frame Depending on the local wind and snow loads additional mounting points may be required Mounting with Clamps If module clamps are used to sec...

Страница 5: ...the 4 mm diameter grounding holes marked as grounding hole on the frame When the module system is used it should be connected to the ground reliably The ground wire should be a naked copper wire with...

Страница 6: ...tch up either Only one type of the same connector from one supplier should be used to ensure the reliability of the electrical connection Module Male connector Female connector Manufacturer Notes ETP6...

Страница 7: ...m2 Equivalent wire should be used if the user prefers to use his own wire When the module s rated current is lower 12AWG wire is recommended for use and the strength of the wire should be taken into c...

Страница 8: ...r sunlight and other light sources Refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 percent 80 percent derating which may be applicable 4 Characterist...

Страница 9: ...9 85 ETM572155 43 30 35 20 600 4 40 4 98 155 12 ETM572160 43 90 35 26 600 4 49 5 07 160 ETM572165 44 12 35 68 600 4 60 5 19 165 15 ETM572170 44 16 36 13 600 4 71 5 3 170 ETM572175 44 25 36 24 600 4 83...

Страница 10: ...a little while open circuit voltage will decrease which will result in a decrease in the module s output power Therefore a lower environmental temperature is most appropriate for the module 5 Operatio...

Страница 11: ...ience and is believed to be reliable but such information including product specification without limitations and suggestions does not constitute a warranty expressed or implied ET Solar reserves the...

Страница 12: ...12 Please consult your dealer or the manufacturer concerning the warranty of your modules 2010 ET Solar Group...

Отзывы: