10 

 

ET-P672275 

43.78 

36.72 

600 

7.49 

7.96 

275 

ET-P672280 

43.78 

36.72 

600 

7.63 

7.98 

280 

 

ET-P660200 

36 

28.75 

600 

7.7 

7.71 

200 

15 

ET-P660205

 

36 

28.75 

600 

7.13 

7.8 

205 

ET-P660210 

36 

28.75 

600 

7.3 

7.99 

210 

ET-P660215 

36 

29 

600 

7.41 

8.1 

215 

ET-P660220 

36.3 

29 

600 

7.58 

8.1 

220 

ET-P660225 

36.3 

29 

600 

7.75 

8.1 

225 

ET-P660230 

36.5 

29.4 

600 

7.82 

8.3 

230 

ET-P660235 

36.5 

29.4 

600 

7.99 

8.3 

235 

 

Usually the load of the modules is a group of batteries. To prevent the modules from 

being charged by batteries under the circumstance of no sunlight, it is important to add a 

shut-off diode in series. Also, please consider the voltage decrease of PN junction of 

about 0.7V when connecting the shut-off diode. The modules can withstand for a 

maximum positive or negative design loading of 45 lbs / ft

2

.

 

 

The  environmental temperature  may also affect the modules’ output power.  If the 

environmental  temperature goes up, the short-circuit current will increase a little,  while 

open-circuit voltage will decrease, which will result in a decrease in the module’s output 

power. Therefore, a lower environmental temperature is most appropriate for the module. 

 

5. Operation and Maintenance  

ET Solar module users should rinse the array seasonally or as needed in dry, dirty areas 

to improve the performance of their solar electrical systems. Heavily soiled modules will 

have a decrease in performance due to reduced light on the photovoltaic cells. Studies by 

the PVUSA in Davis, CA estimate that during a dry year module soiling may affect 

performance by as much as 7% annually with no cleaning. Seasonal rains often clean the 

modules, however, during the long dry summer, it is helpful to rinse the modules as 

needed. 

ET solar modules may be rinsed with clean water to remove dirt. Normal pressure from a 

standard residential hose and nozzle is recommended. Early morning and late afternoons 

are favorable times to clean to avoid a sudden change in temperature. Care must be taken 

since modules produce energy any time light is present. Modules are not to be touched or 

walked on except by a licensed professional. 

 

Содержание ET-P654180

Страница 1: ...solar PV projects around the world 2 Structure of module ET modules are made by layering low iron tempered glass an EVA sticky membrane high conversion efficient solar cells and a behind the membrane...

Страница 2: ...nded that the modules usually face the equator thus in the Northern Hemisphere the surface should be oriented towards the south and in the Southern Hemisphere towards the north Usually the angle betwe...

Страница 3: ...ion The surface of the modules should avoid shadows and be kept clean from foreign materials such as dirt The assembly is to be mounted over a fire resistant roof covering material when roof mounting...

Страница 4: ...s will use the four inner mounting holes on the module frame Depending on the local wind and snow loads additional mounting points may be required Mounting with Clamps If module clamps are used to sec...

Страница 5: ...the 4 mm diameter grounding holes marked as grounding hole on the frame When the module system is used it should be connected to the ground reliably The ground wire should be a naked copper wire with...

Страница 6: ...tch up either Only one type of the same connector from one supplier should be used to ensure the reliability of the electrical connection Module Male connector Female connector Manufacturer Notes ETP6...

Страница 7: ...m2 Equivalent wire should be used if the user prefers to use his own wire When the module s rated current is lower 12AWG wire is recommended for use and the strength of the wire should be taken into c...

Страница 8: ...r sunlight and other light sources Refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 percent 80 percent derating which may be applicable 4 Characterist...

Страница 9: ...9 85 ETM572155 43 30 35 20 600 4 40 4 98 155 12 ETM572160 43 90 35 26 600 4 49 5 07 160 ETM572165 44 12 35 68 600 4 60 5 19 165 15 ETM572170 44 16 36 13 600 4 71 5 3 170 ETM572175 44 25 36 24 600 4 83...

Страница 10: ...a little while open circuit voltage will decrease which will result in a decrease in the module s output power Therefore a lower environmental temperature is most appropriate for the module 5 Operatio...

Страница 11: ...ience and is believed to be reliable but such information including product specification without limitations and suggestions does not constitute a warranty expressed or implied ET Solar reserves the...

Страница 12: ...12 Please consult your dealer or the manufacturer concerning the warranty of your modules 2010 ET Solar Group...

Отзывы: