background image

www.etsolar.hk 

- 9 - 

 

 

Do not disconnect under load'

 

Operation and Maintenance 

 

It  is  required  to  perform  regular  inspection  and  maintenance  of  the  modules, 
especially during the period of warranty. inform the supplier within 2 weeks when 
modules are found to be defective. 
ET  Solar  recommends  the  following  maintenance  items  to  ensure  optimal 
performance of the module. 

 

6.1 Cleaning 

 

This manual covers the requirements for the cleaning procedures of ET Solar PV 
modules.  Professional  installers  should  read  these  guidelines  carefully  and 
strictly follow these instructions. Failure to follow these instructions may result in 
death,  injury,  or  property  damage.  Damages  induced  by  inappropriate 
cleaning procedures will void ET Solar warranty.   

 

The amount of electricity generated by a solar module is proportional to the 
amount of light captured. A module with shaded cells generate less energy, 
and therefore, it is essential to keep PV modules clean. The dirt such as bird 
droppings, leaves, dust is usually need to be cleaned.   

 

When  cleaning  the  modules,  make  sure  that  the  temperature  difference 
between the water and the module is in the range of -5

-10

.   

 

Use a dry or wet, soft and clean cloth, sponge, or soft bristled brush to wipe the 
photovoltaic module. Please make sure that the cleaning tools do not wear 
out glass, EPDM, silicon, aluminum alloys or steel.   

 

If  there  is  greasy  dirt  or  other  substances  which  are  difficult  to  clean, 
conventional household glass cleaning agents can be used. Pay attention not 
to use alkaline and strong acidic solvents, including hydrofluoric acid, alkali, 
acetone.   

 

For modules that are installed horizontally (0° tilt angle),   
they should be cleaned more frequently, as they do   
not have"self-cleaning" function as those installed at   
10° or larger tilt angles.   

 

The back surface of the monofacial module usually 
does not need to be cleaned. When cleaning the back   
of the bifacial module, avoid any sharp objects that   
may cause damage or penetrate the base material. 
The other cleaning requirements are the same as the front-side. 

 

 

 
 

Содержание ET-M660BH GL Series

Страница 1: ...www etsolar hk INSTALLATION MANUAL ET Solar Series Module Installation Safety instructions Maintenance Version 2021Q4...

Страница 2: ...Selecting the proper mounting structure and hardware 4 4 2 Mounting methods 4 4 2 1 Mounting with bolts 4 4 2 2 Mounting with clamping hardware 5 4 2 3 Installation position and static loads 6 5 Elec...

Страница 3: ...ompliance with this installation instruction may result in property damage and or physical injury ET Solar will not be liable for compensation of any loss or injury caused by this type of non complian...

Страница 4: ...re may go outside the above range please consult with ET Solar before installation The irradiance reflected on the rear of the bifacial solar modules shall not exceed 300W m2 Do not attempt to disasse...

Страница 5: ...y a factor of 1 25 when determining component voltage ratings conductor ampacity fuse sizes and size of controls connected to the module or system output An additional multiplying factor of 125 percen...

Страница 6: ...r to standard solar photovoltaic installation guides or a reputable solar installer or systems integrator Shading on the module will reduce electricity production Do not install the module near equipm...

Страница 7: ...big enough to fix the modules steadily Please find detailed mounting information in the below figure A 1 2 4 2 2 Mounting with clamping hardware When choosing clamp mounting method please be sure to u...

Страница 8: ...ion and static loads Maximum design load of the PV module by front 3600pa and back1600pa the safety factor of 1 5 times these values can vary depending on installation method of the modules please ref...

Страница 9: ...ET Solar recommends the negative pole of PV module array is connected to earth during all PV system installations That will keep optimal performance of PV Power Plants which are located in a hot high...

Страница 10: ...if hot spot occurred the diode will come into operation to stop the main current from flowing through the hot spot cells in order to prevent module over heated and performance loss Notice bypass diod...

Страница 11: ...keep PV modules clean The dirt such as bird droppings leaves dust is usually need to be cleaned When cleaning the modules make sure that the temperature difference between the water and the module is...

Страница 12: ...as lubricants and organic solvents to clean the connectors Do not clean modules under the weather conditions of wind more than 4 class in Beaufort scale heavy rain or heavy snow When cleaning the modu...

Страница 13: ...uation are not covered by ET Solar s warranty TROUBLE SHOOTING If your PV system does not work normally after installation please inform your installer immediately It is recommended to perform prevent...

Страница 14: ...ssumed by ET Solar for any infringement of patents or other rights of third parties which may result from use of the PV product No license is granted by implication or otherwise under any patent or pa...

Страница 15: ...www etsolar hk 13 Appendix 1 Electrical ratings of ET Solar modules Sheet 1 solar cell type 166mm...

Страница 16: ...www etsolar hk 14 Sheet 2 solar cell type 158 75mm...

Страница 17: ...www etsolar hk 15 Sheet 3 solar cell type 156 75mm mono si poly si Sheet 4 solar cell type 182mm...

Страница 18: ...www etsolar hk 16...

Страница 19: ...ABOUT MANUFACTURER ET SOLAR POWER HONGKONG LIMITED Room 01 21 F XINGFA Commercial Building 9th Tobacco Factory Street Mong Kok HongKong Tel 86 510 85382358 Fax 86 510 85382358 mail support etsolar HK...

Отзывы: