5.3 GSM settings

GSM SETTINGS

Name

Description

PIN of authorization

Here you should give your PIN code for the 
authorization of GSM connection

Tel. 1

Telephone number1 to which alarm notices will be 
sent 

Telephone 1 active

Turning on/off the  notifications to the telephone 
number 1 indicated

Tel. 2

Telephone number 2 to which alarm notifications 
will be sent

Telephone 2 active

Turning on/off the notifications to the telephone 
number 2 indicated.

* The Vide GSM module has been equipped with Li-ion battery with the capacity of 600 mah. 
In case the external power supply is lost, the module is capable to operate on its own up to 4 
hours.   Change   of   power   supply   mode   always   results   in   sending   the   SMS   alarm   to   active 
telephone numbers.  

5.4 Settings

SETTINGS

Name

Description

Operation with controller

Turning on/off of connection with controller

Contrast of display

Change of display contrast

5.5 Notices

 

NOTICES

Name

Description

Active notice

Allows you to set whether SMS notices about 
active alarms are to be sent. You should also 
remember to set active telephone numbers to 
which notices will be sent.

Time of another alarm

Allows you to set the frequency of time SMS 
with communique about the alarm will be 
sent.

estyma electronics
www.estyma.pl

page 15

PL20130524

Содержание Vide

Страница 1: ......

Страница 2: ...page 2 PL20130524...

Страница 3: ...ons 8 3 Review of functions 9 3 1 Control of binary output 9 3 2 Information about input condition 9 3 3 Information about the controller of boiler 10 3 3 1 Commands of queries about the parameters of...

Страница 4: ...range of room temperature allowed alarm when the input contact is closed or open used for giving notice about the opening shutting of doors gates garages Contact output binary makes the remote activa...

Страница 5: ...n of device in a negative way No objects should be put into the device through gaps for example ventialtion gaps This can cause short circuit fire or damage to the device Take care that no water moist...

Страница 6: ...ning is recommended 1 4 Procedure with the used equipment The electronic device was made from materials which are fit for recycling only in part That is why the device must be returned to the recovery...

Страница 7: ...ing equipment 3 In the place of installation the temperature of ambient cannot exceed 60 C and it should not be lower than 0 C Humidity should range from 5 to 95 without condensation 2 3 Installation...

Страница 8: ...nect the power unit 5V 1 2A CAN Communication interface CAN for connecting the controller of boiler burner Binary output Binary output of open collector type Current efficiency 100mA Contact Contact i...

Страница 9: ...put PIN 1 x x binary output condition 0 lub 1 PIN number assigned in GSM settings 3 2 Information about input condition Query command about the input condition T1 T2 STYK module VIDE GSM Example of re...

Страница 10: ...ode manual Controller condition of controller turned ON turned OFF Burner condition of burner TURNED OFF MODULATION Boiler mode mode of boiler operation MANUAL AUTO Permission permission for the opera...

Страница 11: ...ERMAMENT Estyma Command of query about input condition T1 T2 STYK Example of replies INPUT T1 18 8 Max 26 0 Min 18 0 INPUT Contact OPEN Output turned off 3 3 2 Commands of changes of boiler controller...

Страница 12: ...CO16 Range of setting 15 0 30 0 Example of command 1111 Heating1 Trcs 24 0 Tres Set economical room temperature CO1 CO16 Range of setting 10 0 25 0 Example of command 1111 Heating1 Tres 20 0 Examples...

Страница 13: ...ill cause the sending of alarm SMS Name of input T2 Allows you to give your own name to the input of temperature measurement T2 Min temperature T2 Allows you to set the lowwer temperature limit at inp...

Страница 14: ...of contact Alarm T1 after exceeding the permissible temperature range in the sensor T1 the contact changes into active or inactive indicate in the logics please Alarm T2 after exceeding the permissib...

Страница 15: ...00 mah In case the external power supply is lost the module is capable to operate on its own up to 4 hours Change of power supply mode always results in sending the SMS alarm to active telephone numbe...

Страница 16: ...ch place at home REOMOTE CONTROL PANEL Name Description Boiler Change of the operation mode into automatic or continuous turning on turning off the controller and preview of current temperature Burner...

Страница 17: ...conomical Measured preview of measured temperature Buffer Information about the upper lower set temperature of buffer and temperature measured Solars Information about the condition of solar Alarms In...

Страница 18: ...6 Specification Manufacturer Estyma electronics al Lipowa 4 11 500 Gi ycko POLAND tel 48 87 429 86 75 fax 48 87 429 86 75 biuro estyma pl www estyma pl page 18 PL20130524...

Отзывы: