Content
WATER 1: Thw 44, Thwsc 45, Thwse 30, Program MANUAL
Solar?
Query about the parameters of solar installation
Example of replies:
SOLAR: Power 2500, T1 80.5, T2 100.0, T3 0.0, T4 0.0
Heating1?
Heating2?
..
Heating16?
Query about the parameters of central heating circuits
Explanation of parameters:
Tr – room temperature
Trcs – comfort set
Tres – economical set
Program – program of heating (TIME, PERMAMENT, OFF, ECON)
Example of replies (query: Heating3?)
HEATING 3: Tr 23.0, Trcs 22.0, Tres, 19.0, Program
PERMAMENT
Estyma?
Command of query about input condition T1, T2, STYK:
Example of replies:
INPUT T1 18.8 Max 26.0 Min 18.0
INPUT. Contact OPEN. Output turned off
3.3.2 Commands of changes of boiler controller settings
Module
Command
Description
Boiler:
Tbsm
Set temperature of boiler in manual mode
Range of setting: [40-80]
Example of command:
1111 Boiler:Tbsm=65;
Bmode
Mode of boiler operation
Range of setting: [auto = 1, manual = 0]
Example of command:
1111 Boiler:Bmode=1;
Ctrl
ON/OFF of controller
Range of setting: [
ON = 1, OFF = 0]
Example of command:
1111 Boiler:Ctrl=1;
Burner
Consent for the operation of burner
Range of setting:
[consent = 1, lack = 0]