3 Overview of the basic functions
3.1.3 Graphic display
3.2 Statuses of furnace
Status
Description
TURNED OFF
The burner is not working. Permission to work off.
CLEANING
Cleaning the burner by strong stream of air.
FIRING UP
Firing up fuel.
Providing the initial dose of fuel to run igniter and blower.
INCANDESCING
When the flame in phase of the firing up is discovered, starts
providing additional portions of fuel and increase the power of
blower for arcing furnace.
POWER 1
The burner works with the power first.
POWER 2
The burner works with the power of a second.
MODULATION
The burner works with a modulated power.
BURNING OFF
Quenching of the furnace. Work of burner and blower tray until
the complete disappearance of the flame.
STOP
Burner does not work but it is to agree to his work. The required
boiler temperature is reached.
estyma electronics
www.estyma.pl
page 17