1.
Attach the threaded end of the Air Hose to the Turbine System’s air outlet.
2.
Connect the other end of the Air Hose to the Spray Gun.
Adjusting Flow Control Knob
The Fluid Control Knob is found at the rear of the gun. It controls the amount of solution
that is sprayed through the nozzle. To find the optimal setting for the Fluid Control Knob,
follow the below instructions:
1.
Turn the knob in the clockwise direction so that only air is coming out of the gun. Then
turn the knob counter-clockwise slightly to start the flow of spray.
2.
In each turn, test the spray on a white sheet or towel to check the amount of solution
coming out of the nozzle. Keep doing this until you have a very fine, even “mist” and a
light tan colour is showing on your towel.
3.
Turn the knob clockwise for less solution and counter-clockwise for more solution. The
further you pull the spray gun trigger, the further the needle inside the gun is retracted
and the more solution comes out. About a 5 millimetres trigger pull is ideal.
Setting Spray Pattern
You can adjust the air cap of the Spray Gun to three positions.
•
To produce a horizontal pattern for spraying across.
•
To produce a vertical pattern for spraying up and down
•
To produce a round pattern to spray small areas such as arms or the face.