36
DDE 5500 // DDE 8500
05003-52-02
WARNING
Risk of falling from ladders
Use ladders with a minimum step height of 2 m.
1. Switch product off.
2. Disconnect the compressed air supply.
3. If necessary, empty the compressed air tank by means of manual cleaning.
Wait approx. 5 minutes while the dust is collected in the collection
containers.
4. Unscrew and remove the fastening screws on the cover of the product.
5. Take off the device cover on the handles.
6. Loosen and completely remove the filter cartridges'
fixing nuts.
7. Fold the disposal bag over the edge of the filter
cartridge.
8. As you carefully remove the filter cartridge, the disposal
bag must be pulled over the entire filter cartridge by the
second operator.
9. Fasten the end of the bag securely with a cable tie.
10. Remove remaining filter cartridges as described.
11. Clean the rim around the opening for inserting the filter
cartridge.
Avoid raising dust.
12. Insert the fixing nuts for the filter cartridge and tighten
them.
The filter cartridges have been replaced.