Device Description

General Information

The scope is a wireless sensor with a recording function (datalogging function). The data is
transmitted in real time via Bluetooth broadcasts and stored in parallel in the local memory.
The scope measures temperature, humidity, vibration and movement, brightness and
barometric pressure. Through an interface, the scope can be extended by various
measurement parameters. The scope has a button for switching on and off and interaction
during operation.
Through an electrostatic adhesive strip ("Gecko-strip"), the scope can be attached to smooth
surfaces and removed without leaving any residue easily.
To achieve a 24/7 monitoring the scope can be used in combination with the wireless sensor
infrastructure of

essent

im

. This requires at least one

essent

im

gateway. Further information

can be found at www.essentim.com/en/essentim-sensors.

scope

8

user manual scope - version 1.1

Содержание Scope 4

Страница 1: ...User Guide...

Страница 2: ...essentim GmbH Schragenhofstrasse 35 D 80992 M nchen www essentim com info essentim com 2 user manual scope version 1 1...

Страница 3: ...f 12 Reset 12 User interaction with the scope 12 LED function 13 Find Identify scope App 13 Memory App 13 Operating modes App 14 Magic Time App 14 Dynamic Mode 14 Static Mode 15 Logger Mode 15 Scope d...

Страница 4: ...Disposal 19 Changelog 20 4 user manual scope version 1 1...

Страница 5: ...esulting from the use of the measured values determined Reserve technical changes All rights reserved essentim GmbH Warranty and liability The device complies with the essential health and safety requ...

Страница 6: ...ructions in this user manual the basic work safety regulations must be observed The system is safe and reliable and complies with the relevant EU directives In case of improper use the user third part...

Страница 7: ...ry or mobile measuring unit Scopes must be charged at room temperature but in any case between 0 C and 40 C Only use essentim approved cables and extension in conjunction with the scope Avoid mechanic...

Страница 8: ...e can be extended by various measurement parameters The scope has a button for switching on and off and interaction during operation Through an electrostatic adhesive strip Gecko strip the scope can b...

Страница 9: ...ls or mechanical stress The product must not be sterilized Observe the cleaning instructions in the user manual to avoid damage 0 C to 40 C 10 to 50 Keep away from frost and heat prevent from contact...

Страница 10: ...ng lithium containing batteries Information can be obtained directly from the transport service provider or contact essentim Unused scopes should be stored with a charge of about 30 Note It is recomme...

Страница 11: ...green LED 2 If the scope is not yet switched on press the button briefly to start the scope 3 Seal the interface with the supplied anti dust plug 4 Remove the protective foil from the Gecko strip on t...

Страница 12: ...activated through pushing the button but only by charge When switched on the green LED flashes several times When switched off the red LED flashes several times Reset By pressing the button for 12 5...

Страница 13: ...ort short flashing RED data transmission without time set short flashing once RED Find Identify scope App With the app it is possible to set a flash for 15 seconds at the scope This simplifies e g to...

Страница 14: ...on criterion used is the change of a measured value If the measured value changes steadily the data is transmitted frequently it changes only rarely static ambient conditions and is only transmitted i...

Страница 15: ...essed while the scope is in the receiving area of the sensor network The data can also be requested manually via the app Note Please refer to our video tutorials and the detailed user guide for the ap...

Страница 16: ...proved for sterilization processes of any kind as both thermal and chemical processes can destroy the scope and can lead to property damage and personal injury Maintenance and Repair Checking the meas...

Страница 17: ...a essential apps via Bluetooth 2 How can I set the time of the scope The time is automatically set as soon as the scope is connected to a sensor network or connected to an essentim app The time is a p...

Страница 18: ...gnal from the scope Bring the scope closer to the scouter 3 Data points are missing although the scope was on and loaded all the time The scope was outside the receiving range Move the scope close to...

Страница 19: ...pe must be completely discharged so that it can not be switched on again by a button pressure The devices can be brought to collection points for waste electrical and electronic equipment for disposal...

Страница 20: ...enungsanleitung 21 08 2018 berarbeitung der Bedienungsanleitung 18 09 2018 bersetzung der Bedienungsanleitung Englisch 14 03 2022 Design Aktualisierung 22 04 2022 Entfernung der EG Declaration of Conf...