Controlling and Using Z-Wave Devices
WeR@Home™ Z-Wave® User Guide
23
Inputs and Outputs
Status
The cannon is armed and a detection is made.
The firing capability is enabled.
The cannon is fired.
6.3.4
Defining the Cannon Required Rules
To operate the MIMO smoke cannon, you must define the following four rules:
Table 2: MIMO Smoke Cannon Rule Definitions
Rule
Trigger
Action
Arm rule
Arm Away
MIMO Output 1 : Arm
Select
Arm
Disarm rule
Disarm
MIMO Output 1 : Disarm
Select
Disarm
Smoke liquid status
MIMO Input Range : Liquid
Send notification
For example: “Problem with smoke-generating liquid
reported.”
Cannon error status
MIMO Input Range : Error
Send notification
For example: “General error with smoke cannon reported.”