Страница 1: ...Care Home Motion Detector User Guide ESUGSC008 Version 2 0 September 2017...

Страница 2: ...8 2 2 Checking if an Optical Limiter is Required 10 2 3 Checking if a Pet Immune Lens is Required 11 2 4 Setting Up the PIR 11 2 5 Conducting a Walk Test 22 3 Operating the PIR 23 3 1 Notifications 2...

Страница 3: ...Home Motion Detector User Guide 3 1 Overview The Essence Passive Infrared Detector PIR is a battery operated bi directional wireless motion detector Figure 1 Essence Passive Infrared Detector Dragonfl...

Страница 4: ...etermine the best location Check if an optical limiter is required Check if a pet immune lens is required Set up the PIR Conduct a walk test 2 1 Determining the Best Location When selecting a mounting...

Страница 5: ...uide 5 A surface that is clean dry and smooth At a height of 2 to 2 2 m 6 6 to 7 2 ft Within 400 m 1 312 ft of the control panel CP NOTE The PIR has a maximum detection range of 12 m 40 ft and maximum...

Страница 6: ...ions to Avoid The mounting location should not be On a door frame Where objects obscure the coverage area even partially For example bookcases or cabinets A location that has moving objects in the cov...

Страница 7: ...he door when the resident passes the open bathroom door through the hallway the PIR sends a bathroom event to the CP reporting incorrectly that the resident is entering the bathroom A location that ha...

Страница 8: ...Room Recommendations To get the best from the PIR take account of the following recommendations for mounting locations in different room types Bedroom Install the PIR opposite the bed to ensure the e...

Страница 9: ...restroom activities Refer to 2 2 Checking if an Optical Limiter is Required on page 10 NOTE In a combined bathroom if an optical limiter is fitted to the restroom PIR the coverage area of the two PIRs...

Страница 10: ...r installation when a living room is adjacent to the dining room Figure 4 Combined Living Room and Dining Room 2 2 Checking if an Optical Limiter is Required If the premises include rooms that combine...

Страница 11: ...f the resident and the movement of the pet by using a pet immune lens Instructions for fitting a pet immune lens are included in 2 4 Setting Up the PIR on page 11 The following figure shows the pet im...

Страница 12: ...ward Figure 7 Release the Mounting Base NOTE Refer to Using Screws on page 29 for information about installing the PIR using screws 4 Peel off the protective strips from the mounting tape required for...

Страница 13: ...n Detector User Guide 13 5 Press the mounting base into place ensuring it is the right way up Figure 9 Put the Mounting Base the Right Way Up 6 Remove the battery cover by sliding it upwards Figure 10...

Страница 14: ...ep 16 on page 19 8 Unscrew the two screws above the battery compartment at the top of the back cover Figure 11 Unscrew the Screws 9 Insert a flat screwdriver between the tab of the front panel and the...

Страница 15: ...PIR Figure 13 PIR Front Panel and Back Cover Caution Be careful not to damage the internal parts of the PIR 10 To install the pet immune lens in the PIR a Use a flat screwdriver to release the three l...

Страница 16: ...IR front panel The pet immune lens fits inside the opening of the PIR Figure 15 Insert the Pet Immune Lens c Insert the PIR outer lens on top of the pet immune lens in the groove surrounding the openi...

Страница 17: ...t at the top of the oval opening in the PIR front panel Figure 17 Insert the Optical Limiter b Push the limiter until it completely fits into place Otherwise the PIR cannot close properly Figure 18 Op...

Страница 18: ...cover onto the front cover aligning the latch tab with the lock tab of the front panel Figure 20 Put the Back Cover onto the Front Cover 14 Holding the PIR with the back cover facing you press your t...

Страница 19: ...the PIR is part of a Care Home kit a Move the PIR at least 2 m 6 ft 7 in from the CP b Shake the PIR gently The rattling sound is the tamper prevention mechanism c Insert the battery observing the cor...

Страница 20: ...ure 24 Press the CP PAIRING Button b Move the PIR at least 2 m 6 ft 7 in from the CP c Shake the PIR gently The rattling sound is the tamper prevention mechanism d Insert the battery observing the cor...

Страница 21: ...and the CP ring lights up red for two seconds Try to pair the PIR again Already paired The CP beeps the CP ring lights up blue and the EMERGENCY button lights up red NOTE If no additional peripheral...

Страница 22: ...st mode starts automatically after the PIR powers up such as When a new battery is inserted After adding and pairing a new PIR with the Care Home system This mode lasts 10 minutes During the Walk Test...

Страница 23: ...low The PIR tamper switch is disturbed 3 2 Supervision The PIR is a supervised device The PIR periodically transmits its status to the CP If after a pre defined time the CP does not receive the status...

Страница 24: ...eplaced WARNING A new battery can cause damage if it is incorrectly installed Be careful to replace the battery only with the same or equivalent to the recommended type Refer to 5 Specifications on pa...

Страница 25: ...ery Cover 3 Remove the old battery 4 Shake the PIR gently The rattling sound is the tamper prevention mechanism 5 Insert the new battery observing the correct polarity When the battery is installed th...

Страница 26: ...r up and periodically Optical Sensor Dual element low noise pyro ceramic sensor RFI shielding Insect immunity sealed optics Lens White ESI 4th generation DragonflyEye multi zone lens 12 m 39 ft detect...

Страница 27: ...s Walk test Automatic after power up for 10 minutes Visual indications LED for detection tampering and walk test Environmental RFI protection Over 30V m Operating temperatures 0 to 49 C 32 to 120 2 F...

Страница 28: ...n method consider the following Installation with mounting tape is more common Installation with screws is recommended when installing the PIR at an angle Using Mounting Tape Mounting tape is approved...

Страница 29: ...at an angle 6 for installation in a corner A standard Philips screwdriver Installing the PIR with Screws To install the PIR using screws 1 Release the PIR mounting base by lifting the tab and pushing...

Страница 30: ...screw holes to use for each type of installation The corner support holes are blocked by the mounting tape You can drill through the tape Figure 29 Holes for Installing on a Flat Wall Figure 30 Holes...

Страница 31: ...o you some or all of the above disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without regard to pri...