Installing the FL
Care@Home™ Flood Detector User Guide
7
The red LED lights up, indicating that the FL is operational.
Figure 5: LED
7.
Test the FL:
a.
Place the flood sensor in water.
b.
Verify that the LED lights up red.
c.
Verify that the CP and monitoring station receive notification of a possible flood event by
checking the
Events History
page of the
Care
web application. Refer to ESUG05051
Care@Home™ Administrator User Guide.
d.
Remove the flood sensor from the water and make sure it is dry.
e.
Verify that the LED lights up green.
f.
Verify that the CP and monitoring station receive notification of the end of the flood threat by
checking the
Events History
page of the
Care
web application.
8.
If the FL does not pass the test:
a.
Open the FL
b.
Take out and check the battery
c.
Set up the FL again by starting at step number 2
9.
Once the FL has passed the test, clean the surfaces of the mounting locations thoroughly. Make
sure the locations are dry.
NOTE:
Refer to Using Screws on page 15 for information about installing the FL
using screws.
LED