Operating the Bed Sensor 

 

 

Care@Home™ Bed Sensor User Guide 

 

3.

 

Operating the Bed Sensor  

The bed sensor monitors certain events, and reports them by: 

 

LED indications 

 

Sending notifications to the CP 

3.1.

 

LED Indications 

The bed sensor LED lights for the following events: 

 

Red – Battery replaced 

 

Green – Pad pressed 

3.2.

 

Notifications 

The bed sensor sends notifications to the control panel for the following events: 

 

Pressure is applied to the pad 

 

Pressure is released from the pad 

 

The battery is low 

 

The tamper switch is activated 

3.3.

 

Supervision 

The bed sensor is a supervised device. The bed sensor periodically transmits its status to the control 
panel. If after a pre-defined time the control panel does not receive a status message, the control 
panel sends a supervision lost message to the monitoring station. 

The bed sensor's state, pressed or not pressed, is included in periodic updates. 

Содержание Care@Home ES700BD

Страница 1: ...Care Home Bed Sensor User Guide ESUGSC104 Version 1 0 February 2019...

Страница 2: ...Bed Sensor 4 2 1 Required Items 4 2 2 Pairing the Bed Sensor 4 2 3 Placing the Bed Sensor 6 2 4 Associating the Bed Sensor with a Motion Detector 7 3 Operating the Bed Sensor 8 3 1 LED Indications 8...

Страница 3: ...ireless sensor for detecting the resident s presence in bed Care Home uses the bed sensor together with an associated motion detector PIR to determine if the resident is in the bedroom The bed sensor...

Страница 4: ...ed sensor with a motion detector 2 1 Required Items Ensure you have the following One 3 V CR123A lithium battery A flat headed screwdriver 2 2 Pairing the Bed Sensor You need to pair the bed sensor wi...

Страница 5: ...damage if it is installed incorrectly 6 Continue to hold the tamper switch until the control panel responds 7 Ensure that pairing was successful based on the response you receive from the control pane...

Страница 6: ...h the mounting base to the transmitter The LED lights red 2 3 Placing the Bed Sensor Proper placement of the bed sensor is important for accurate detection and the resident s comfort The pressure pad...

Страница 7: ...te a bed sensor with a motion detector using the Care Home web application 1 Log on to the Care Home web application 2 Click Users A list of users appears 3 Click the name of the resident The Resident...

Страница 8: ...nds notifications to the control panel for the following events Pressure is applied to the pad Pressure is released from the pad The battery is low The tamper switch is activated 3 3 Supervision The b...

Страница 9: ...ry 1 Insert a screwdriver into the transmitter s slot and press the tab to release the mounting base 2 Remove the old battery 3 Press the tamper switch several times 4 Insert the new battery observing...

Страница 10: ...curity 32 bit ID over 4 billion combinations Transmitter Security Tamper mechanism for open cover Sensitivity Nominal detection threshold 22 kg 50 lbs Power Consumption Batteries 3V CR123A lithium bat...