Specifications 

 

10 

 

Care@Home™ Bed Sensor User Guide 

 

5.

 

Specifications  

Item 

Data 

Part Number 

ES700BD 

Communications 

 

Maximum RF range:

 Up to 400 m (1,312 ft.) – open air 

 

Protocols:

 Proprietary bi-directional radio protocol 

 

Modulation and frequency

: FSK modulation: 

 

868.3 MHz (China) 

 

869.225 MHz (Europe) 

 

916.5 MHz (North America and Australia) 

 

916.3 MHz (Israel) 

 

Data security

: 32-bit ID, over 4 billion combinations 

Transmitter 
Security 

 

Tamper mechanism for open cover 

Sensitivity 

 

Nominal detection threshold: 22 kg (50 lbs.) 

Power 
Consumption 

 

Batteries: 3V CR123A lithium battery 

 

Battery life: Up to 3 years 

Dimensions 

Size

 (H x W x D): 

 

Transmitter: 98 x 25 x 25 mm – 3.86 x 0.98 x 0.98 in. 

 

Pressure pad: 76.2 x 27.94 x 0.8 cm – 30 x 11 x 0.3 in. 

Environment 

 

Storage ambient temperature range: -20ºC – 70ºC (-4ºF – 
158ºF) 

 

Operating ambient temperature range: 0ºC – 49ºC (32ºF – 
120ºF) 

 

Operating humidity: Up to 93% non-condensing 

Compliance 

 

CE, FCC, IC, UL 

 

 

Содержание Care@Home ES700BD

Страница 1: ...Care Home Bed Sensor User Guide ESUGSC104 Version 1 0 February 2019...

Страница 2: ...Bed Sensor 4 2 1 Required Items 4 2 2 Pairing the Bed Sensor 4 2 3 Placing the Bed Sensor 6 2 4 Associating the Bed Sensor with a Motion Detector 7 3 Operating the Bed Sensor 8 3 1 LED Indications 8...

Страница 3: ...ireless sensor for detecting the resident s presence in bed Care Home uses the bed sensor together with an associated motion detector PIR to determine if the resident is in the bedroom The bed sensor...

Страница 4: ...ed sensor with a motion detector 2 1 Required Items Ensure you have the following One 3 V CR123A lithium battery A flat headed screwdriver 2 2 Pairing the Bed Sensor You need to pair the bed sensor wi...

Страница 5: ...damage if it is installed incorrectly 6 Continue to hold the tamper switch until the control panel responds 7 Ensure that pairing was successful based on the response you receive from the control pane...

Страница 6: ...h the mounting base to the transmitter The LED lights red 2 3 Placing the Bed Sensor Proper placement of the bed sensor is important for accurate detection and the resident s comfort The pressure pad...

Страница 7: ...te a bed sensor with a motion detector using the Care Home web application 1 Log on to the Care Home web application 2 Click Users A list of users appears 3 Click the name of the resident The Resident...

Страница 8: ...nds notifications to the control panel for the following events Pressure is applied to the pad Pressure is released from the pad The battery is low The tamper switch is activated 3 3 Supervision The b...

Страница 9: ...ry 1 Insert a screwdriver into the transmitter s slot and press the tab to release the mounting base 2 Remove the old battery 3 Press the tamper switch several times 4 Insert the new battery observing...

Страница 10: ...curity 32 bit ID over 4 billion combinations Transmitter Security Tamper mechanism for open cover Sensitivity Nominal detection threshold 22 kg 50 lbs Power Consumption Batteries 3V CR123A lithium bat...

Страница 11: ...you some or all of the above disclaimers exclusions or limitations may not apply to you By using the information contained herein you agree that the laws of the State of Israel without regard to princ...

Отзывы: