Pagina 12
STARTING
¾
After the connection, make sure that the red LED
(indicating the device operation status) located on
the GSM200 module is switched on and stays lit
for a few seconds before it starts blinking. In case
the red LED should not be blinking, the GSM
module would not be correctly registered to the
GSM network provider. Disconnect the GSM200
and make sure that the SIM card has been
correctly inserted and no PIN is on.
For a correct registration of the GSM200 module you
must wait 1 minute’s time.
¾
Check the signal strength by means of the green
LED located on the GSM200 module (see
paragraph:”Signalling”).
Note: the signal strength is also indicated
by the specific LED located on the
elevator alarm system.
Note: when connected to the Helpy
L200/Helpy L200 TL, the green
LED (signal strength) located on
the GSM200 module is not
working. C
heck the signal strength
by means of the LED indicating the
device operation status located on
the Helpy L200/Helpy L200 TL. (See
the Helpy L200/Helpy L200 TL user
manual).
¾
If the signal strength is good, proceed with a test
call and mounting operations (see the following
paragraphs).