COMMISSIONING  CHECKLIST  

  
To  assist  with  any  potential  guarantee  claim  please  complete  the  following  information:-­‐  

To  be  completed  by  the  installer.  

  

Dealer  the  appliance  was  purchased  from:  

Name:  

Address:  

  

Telephone  No:  

  

ESSENTIAL  information:  

Date  Installed  

Model  Description:  

Serial  No:  

  

Installation  Engineer:  

Company  Name:  

Address:  

  

Telephone  No:  

  

Commissioning  Checks  

ʹ

  to  be  completed  and  signed:  

  

  

  

  

  

Is  the  flue  system  correct  for  this  appliance?  

Yes     

No     

Flue  swept  and  checked  for  soundness?    

Yes     

No     

Smoke  test  completed  on  installed  appliance?  

Yes     

No     

Spillage  test  complete?  

Yes     

No     

Has   the   use   of   the   appliance,   operation   and   controls   been  
explained?  

Yes     

No     

Clearance  to  combustible  materials  checked?  

Yes     

No     

Instruction  book  handed  to  the  customer?  

Yes     

No     

CO  Alarm  fitted?  

Yes     

No     

  
  

^ŝŐŶĂƚƵƌĞ͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͗͘͘WƌŝŶƚEĂŵĞ͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͙͗

  

Содержание ESSE 1

Страница 1: ...ESSE 1 Smoke Exempt Wood Burning Stove INSTALLATION USER INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER GB IE...

Страница 2: ...ified and corrected Seek expert advice if necessary x Do not fit an extractor fan in the same room as the appliance x It is important that flue ways are cleaned frequently and the chimney swept regula...

Страница 3: ...ommended as suitable for use in smoke control areas when burning dry wood logs in accordance with these instructions Peat and other unauthorised fuels must not be burnt in this appliance in smoke cont...

Страница 4: ...any part of the chimney x Voids in the chimney should be avoided as these will prevent a steady flue draught x The stove flue pipe should pass beyond the narrowing of the chimney see Fig 1 x Considera...

Страница 5: ...Page 5 ONE SE I07 190619 Fig 1 Ideal Flue Connections Flue box available from www esse com Fig 2 Chimney and Flue Performance...

Страница 6: ...draught reading should now be taken with both air controls fully closed MAXIMUM The primary air intake can now be opened to allow the stove to burn at maximum rate Give the stove some time for the bur...

Страница 7: ...ce the draught through the stove if the flue draught is too high The flue stabiliser should be x Fitted in the same room as the stove x The same size as the flue pipe x Fitted no closer than 700mm to...

Страница 8: ...Page 8 ONE SE I07 190619 Fig 3b ESSE 1 with Log Box Dimensions...

Страница 9: ...be removed to access the bolts attaching the rear flue connection the convector panel must first be removed see Fig 4 A rear flue box attachment is also available from www esse com that allows the sto...

Страница 10: ...Fig 5 Stove features When positioning the stove the two rear legs are fitted with adjustment plates to accommodate for hearth variations With the stove in place loosen the required wing nut and slide...

Страница 11: ...ALLING THE ADDITIONAL REAR HEAT SHEILD The additional heat shield kit Part No FM5 048 should be fitted to the stove prior to connecting the flue pipe 1 Remove the 4 screws labelled A 2 Screw in the th...

Страница 12: ...ber to refit the Stove data label on the rear spacer labelled D Installing the optional log box 1 Remove the levelling discs from the back of the stove and fit to the back of the log box 2 The stove c...

Страница 13: ...Serial No Installation Engineer Company Name Address Telephone No Commissioning Checks to be completed and signed Is the flue system correct for this appliance Yes No Flue swept and checked for sound...

Страница 14: ...Page 14 ONE SE I07 190619...

Страница 15: ...liance especially the external surfaces will be hot to touch when in operation and due care will need to be taken It is essential that the fire has adequate air supply for combustion and ventilation A...

Страница 16: ...excess smoke The appliance must not be operated with the appliance door left open except as directed in the instructions DAMPERS LEFT OPEN You may experience excessive smoking if too much air is allow...

Страница 17: ...box Place a firelighter in the space and surround with a small amount of kindling Lay a third log over the top of the space perpendicular to the other logs Fig 8 Final log in position When you are rea...

Страница 18: ...leanest combustion Before lighting a full fire in the stove for the first time it is recommended that 3 smaller fires are lit first to ensure that any moisture is driven out For the cleanest burn usin...

Страница 19: ...he air controls open until the moisture is driven out of the wood and the stove is back up to an efficient operating temperature The air inlets can then be reduced to hold the temperature of the stove...

Страница 20: ...ure that the stove is cold and not lit Open the door and remove all the ash any unburnt material and the vermiculite bricks 2 Insert both solid mineral fuel burning rear bricks Part No FM5 040 There a...

Страница 21: ...eral fuel bottom side brick on the Right hand side of the Stove Part No FM5 046 FM5 041 then fit the remaining solid mineral fuel top side brick on the right hand side of the stove FM5 042 You may hav...

Страница 22: ...t of fuel the grate should be de ashed and the ash pan emptied Add the fuel sloping it from the front coal bar up to the back of the stove to the level of the top of the back brick Open the primary ai...

Страница 23: ...ucts will expand and contract A ticking noise may occur This is normal for this type of appliance TECHNICAL INFORMATION Normal heat output wood 5 0kW Nominal heat output solid mineral fuel 5 0kW Weigh...

Страница 24: ...Page 24 ONE SE I07 190619...

Страница 25: ...to paint The door glass is made of a special heat resisting ceramic and may be cleaned when cold with proprietary glass cleaning liquids and a dry cloth SHUTTING DOWN THE STOVE LONG TERM The following...

Страница 26: ...arts deemed to be replaceable or service parts that may be replaced during the normal usage of the appliance x Damage caused by impact spillage water ingress or condensate attack from flue or by using...

Страница 27: ...Page 27 ONE SE I07 190619 SPARE PARTS Only genuine ESSE spare parts are recommended Parts that may need occasional replacement are Fig 9 Wood Burning Parts...

Страница 28: ...Page 28 ONE SE I07 190619 Fig 10 Solid Fuel Burning Parts...

Страница 29: ...Page 29 ONE SE I07 190619 Fig 6 Additional Parts PART No DESCRIPTION IMAGE FM5 014 DOOR GLASS FM5 048 REAR HEATSHEILD KIT...

Страница 30: ...Page 30 ONE SE I07 190619...

Страница 31: ...Page 31 ONE SE I07 190619...

Страница 32: ...Page 32 ONE SE I07 190619 ESSE Engineering Limited Ouzledale Foundry Long Ing Barnoldswick Lancashire BB18 6BJ Tel 01282 813 235 Fax 01282 816 876 Web www esse com...

Отзывы: