32
PREPARING FOR THE INSTALLATION
PREPARING FOR THE INSTALLATION
Cash Drawer Controller Register
RS232 Control (B-615 / B-615S)
Model
B-615
B-615S
COM port:
COM6
COM5
IO address:
288
2F0
Baud rate:
1200
9600
Open command:
01h
07h
Respond command:
02h
02h
GPIO Control (B-615S / B-815)
The Cash Drawer Controller use one I/O address to control the Cash Drawer.
Register Location:
48Ch
Attribute:
Read/Write
Size:
8bit
NOTE:
The Y cable used to support two cash drawers on the one RJ-11 is same as is used on
Epson printers.