26 of 42
V 1.9
www.esavep.com
PASHW-003-100LD
iv. where a single pipe serves a number of discharges, such as in
blocks of flats, the number served should be limited to not more than
6 systems so that any installation discharging can be traced
reasonably easily. The single common discharge pipe should be at
least one pipe size larger than the largest individual discharge pipe
(D2) to be connected. If unvented hot water storage systems are
installed where discharges from safety devices may not be apparent
i.e. in dwellings occupied by blind, infirm or disabled people,
consideration should be given to the installation of an electronically
operated device to warn when discharge takes place.
10.0 MOVING THE UNIT
10.1 Storage and Transportation
Generally, it's better to use a container to transport hot water heat pumps
and store them in a suitable and dry place.
10.3 Using a Forklift
When using forklift to carry the unit it must be on a pallet and the operator
should try to keep the height of forklift at the lowest possible level because
unit is top-heavy.
10.3 Transportation for Installation
The unit must be kept at vertical for at least 1 hour before you attempt to
start it.
DO NOT TURN UPSIDE DOWN