3.2 Dehumidification –
The Ecocent can be used to dehumidify rooms that
are hot and damp – e.g. Laundry room (See Picture 2). The unit is equipped
with a condensate drain that must be properly directed to a suitable waste
pipe where the condensate water (non acidic) can drain away. If the drain is
into a main sewer it must have a trap installed to prevent back smell through
the Ecocent.
Picture 2
3.3 Cooling
(picture 3)
The Ecocent can extract warm air and place cooled, dehumidified, outlet air
back in to the same room – this is perfect for cellars and gymnasiums. Any
cold air exhaust air ducting must be lagged when passing through a
warmer