1-GENERAL WARNINGS AND REQUIRED CONTROLS 

 

Please read this instruction carefully before proceeding and do not perform undefined operations, use the product in 

accordance with the information contained in this instruction manual and its label, otherwise the product may not operate 

properly,  or  be  injured  or  damaged.  All  operations  described  in  this  manual  should  only  be  carried  out  by  qualified 

personnel who have been approved by the competent authorities. 

 

End users and unauthorized persons should read this instruction, comply with all safety rules that may concern them, in 

any case not to interfere with the product or even to interfere, to change the setting and to try to make physical entry, to 

detect  malfunction  or  gas  leak.  The  regulator  must  close  the  inlet  valve  on  the  front  and  inform  the  relevant  gas 

distribution company and the specialist. The regulator is not allowed to smoke or fire until 2 meters away. 

 

Do not start operations without accessing and reading this instruction. If you cannot reach this instruction, there are topics 

that are not understood, unknown or sure before starting any operation, or you cannot carry out the operation if you 

follow the instructions written in the instructions during operation and if you are having problems, please contact us or 

our representative. 

 

For all operations in this order and during use; Use appropriate tools and methods. We ensure that products or boxes are 

not dropped, thrown, shaken, overburdened, force and impacted, not crushed, no weight placed on them, no damage to 

external parts and external protrusions, no heavy loads and no overturns in all processes and use. 

 

During any operation, before, during and after all use of the product; provide to take all necessary precautions including 

personal protection, take the necessary legislations, regulations, procedures in accordance with the technical standards 

and rules of the gas organizations, take all necessary precautions against the risk of fire, take in the inhalation of the gas, 

take the necessary legal precautions, inform and warn all the interested parties about the transactions, take precautions 

against hazard combinations, take adequate precautions against possible flushing of liquids in line, prevent foreign matter 

from entering the discharge hole, avoid explosion and fire-related substances such as fire, sparks and cigarette smoke due 

to combustible gas and to not used. 

 

Parts other than those supplied with the product and box that are not original and do not belong to my company should 

not be used. Contact us to supply spare parts. All necessary actions and precautions should be taken in consideration that 

they may be exposed to natural phenomena as Product earthquake, flood etc.. At the end of its life, products must be 

replaced with new ones. 

 

Do not attempt to remove the product shut-off bracket and product bracket from the ground, allow mechanical damage 

to be exposed, move to the right or to the left unnecessarily, and do not overstress during any stage and use in this manual. 

 

Keep this instruction in a safe area after all operations. Failure, damage, accident etc. due to failure to follow the rules and 

information in this instruction The manufacturer is not responsible for these situations. Do not exceed the technical limits 

in this instruction. 

 

2-OPERATION-TERMS OF USE AND TECHNICAL SPECIFICATIONS:

 

The  gas  pressure regulator helps the subsequent devices in  the gas line to operate safely. The  gas pressure regulator 
maintains the outlet pressure within the tolerance range by lowering the inlet pressure to the desired / adjusted outlet 
pressure and automatically detects the outlet pressure in the event that the outlet pressure does not reach undesirable 
levels on the safety regulator, or automatically detects this situation, Has a high and low pressure gas safety shut-off device 

Содержание ERG-SR

Страница 1: ...ly be installed by authorized people This product must be assembled in accordance with current regulations and guidelines ESKA VALVE A Sakarya 1 Organize Sanayi B lgesi Mahallesi 11 Cadde No 6 8 Arifi...

Страница 2: ...ions procedures in accordance with the technical standards and rules of the gas organizations take all necessary precautions against the risk of fire take in the inhalation of the gas take the necessa...

Страница 3: ...pressure range etc Depending on the factors The final technical information of the product is stated on the product label In no case should the following restrictions be used Area of Use Service stat...

Страница 4: ...ct label and that the regulator capacity will not be exceeded during use Sufficient tampon volume should be left at the line outlet after the regulator before assembly For products with outlet pressur...

Страница 5: ...with a connection greater than the diameter of the connection on the product s body are to be fitted to the inlet and outlet of the product for assembly the forces and moments which are exceeded by t...

Страница 6: ...nd the gas leakage can be detected by suitable foam detector etc check with the gauges inform the gas users about the gas usage Depending on the temperature difference during the set up process or sea...

Страница 7: ...igure 6 5 PARAMETERS For various reasons if necessary the product outlet pressure and safety shutdown pressure settings should be made as follows The settings should not be changed by more than 10 and...

Страница 8: ...vers that you have removed keep the covers as a group and clean them gently with a clean cloth 22 by pulling the money by hand raising the 17 up part then 22 part then 17 part Remove the 24 way screws...

Страница 9: ...14 15 16 18 10 11 5 2 4 25 1 P6 External leakage 16 18 1 P7 High exit pressure except tolerances 8 7 2 1 P8 Low exit pressure except tolerances 16 18 5 6 3 2 1 P9 Evacuation system mistakes 7 8 2 1 P...

Страница 10: ...lieves the valve a bit relieves the pressure squeeze out instantaneously and then restore all operations 14 Set up shut off no 2 if the door is closed replace the product and check the result 15 Check...

Страница 11: ...11 Figure 2 Figure 4...

Страница 12: ...12 Figure 8 10 LABEL INFORMATION Pds Output Setting Pressure Pdso High Pressure Safety Closure Setting Pressure Pdsu Low Pressure Safety Closure Setting Pressure...

Страница 13: ...atural Gas LPG 11 STORAGE STORAGE LIFTING LOWERING MOVE LOADING TRANSPORT Do not remove the product from its original box and their sleeves unless the use is started do not change the box and its slee...

Страница 14: ...B Uygunluk De erlendirme Y ntemi 2014 68 EU PED Category IV Modul B D Modul B Certificate No Valid Until Modul D Certificate No Valid Until 07 202 9280 Z 0040 18 D 0062 24 01 2028 07 202 9280 Z 0088 1...

Страница 15: ...4 84 E mail info eskavalve com Authorized Signature Company Stamp The Vendor s Title Address Telephone Fax E mail Authorized Signature Company Stamp The Product s Type Gas Pressure Regulator Brand ESK...

Страница 16: ...ses the right to receive free repair if the product breaks down again within warranty period if the maximum time provided for repair is exceeded if the authorized service station Seller manufacturer o...

Отзывы: