background image

 

 
 

Art. No. 11340  

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11340 V2.0 R1.0  Manual 

Page 3 of 9 

 

Conformity 

EN 50090-2-2 
EN 61000-4-2, ESD 
EN 61000-4-3, HF 
EN 61000-4-4, Burst 
EN 61000-4-5, Surge 
EN 61000-6-1, Noise immunity 
EN 61000-6-3, Interference radiation 
RoHS 
 

Display LED  

The module has various display LEDs. In the following the function of the displays  

 
Display 

 
Description 

 
Function 

LED Green 

PWR 

Display for supply voltage 

LED Green 

DATA 

  LED flashes 3 times after power on 

  Flashes at 1-Wire activity 

  Flashes while transferring data by the data interface 

  Flashes very quickly if "KAL Receive" has been activated 

and the 

“KAL messages" of the control system are missing. 

LED Yellow  
Data interface 

 

Network Link LED 
Lights up when a network connection is established   

LED Green  
Data interface   

 

Network data LED 
Lights up during data communication via the data interface  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Auto-E-Connect 11340

Страница 1: ...ing to the safety notes 2 Product description You can communicate with your smart home or industrial controller e g ESERA Station IP Symcon Loxone or FHEM via TCP or UDP protocol with the 1 Wire Controller 2 Autonomous management The 1 Wire Controller 2 is designed for the autonomous management of a 1 Wire Network You no longer need to worry about 1 Wire commands or formulas for evaluating sensor ...

Страница 2: ... of 1 Wire sensors and actuators on the 1 Wire bus It is optimized for industrial applications and enables significant added value beyond the sensor and chip data The Auto E Connect function automatically recognizes ESERA chips sensors and actuators starts suitable libraries and outputs fully formatted data The Auto E Connect functionality will be available from mid 2020 via 1 Wire Controllers 1 W...

Страница 3: ... 3 Interference radiation RoHS 7 Display LED The module has various display LEDs In the following the function of the displays Display Description Function LED Green PWR Display for supply voltage LED Green DATA LED flashes 3 times after power on Flashes at 1 Wire activity Flashes while transferring data by the data interface Flashes very quickly if KAL Receive has been activated and the KAL messa...

Страница 4: ...c duplication of this user guide complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 4 of 9 8 Connection www esera de ...

Страница 5: ...for digital output 5 26 Digital output 5 normally open contact max 5A 30 Reset Button inside 32 GND negative 1 Wire Bus 33 1 Wire Data 34 5 V voltage supply for 1 Wire Bus max 200 mA 35 12 V voltage supply for 1 Wire Bus max 250 mA Module bottom side supply voltage digital input and analog output 1 GND negative digital input isolated to negative supply 2 digital input 1 10 30 VDC 3 digital input 2...

Страница 6: ... complete or in part requires the written consent of ESERA GmbH Errors and technical modification subject to change ESERA GmbH ESERA Automation 2020 www esera de 11340 V2 0 R1 0 Manual Page 6 of 9 9 Connection example 1 Wire Controller sensors and actuators and termination www esera de ...

Страница 7: ...gration in FHEM For the integration into the open source automation software FHEM we provide a software module for easy integration of the 4 fold analog input into FHEM via 1 Wire Controller 1 Wire Gateway Thus evaluation scripts are no longer necessary Details can be found on the ESERA website under Compatible controllers Central FHEM integration Further details can be found on our webpage https ...

Страница 8: ...where flammable gases vapours or dust are present or could be present 18 Assembly The installation site must be protected against moisture The device may only be used in dry indoor rooms The device is intended for mounting inside a control cabinet as a stationary device 19 Disposal note Do not dispose of the device within the household waste According to the directive concerning old electrical and...

Страница 9: ...r damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from unauthorized usage and other legal grounds are excluded Excepting to this ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If...