background image

 

 
 

 Art. No. 11228 V2  

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH, ESERA-Automation 2020 

www.esera.de 

11228 V2.0 R1.0  Manual 

Page 7 of 7 

 

In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary. 

 

For operational and connection errors outside of our control, we assume no liability of any kind for any resulting 
damage. 

 

Kits should be returned without their housing when not functional with an exact error description and the 
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or 
disassembly of cases charges will be invoiced. 

 

During installation and handling of components which later have mains potential on their parts, the relevant VDE 
regulations must be observed. 

 

Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified 
electrician and put into operation. 

 

Commissioning may only be realized if the circuit is built into a contact proof housing. 

 

If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be 
installed upstream or a suitable power supply can be used.  

 

After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, 

https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance

must be carried out. 

 

16 

Warranty 

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship 
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of 
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for 
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, 
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to 
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. 
Claims made under the Product Liability Act are not affected. 
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is 
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. 
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical 
or electronic errors in the online offer. 
We are constantly developing our products further and reserve the right to make changes and improvements to any of the 
products described in this documentation without prior notice. Should you require documents or information on older 
versions, please contact us by e-mail a

[email protected]

 

17 

Trademarks 

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are 
trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their 
respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, names 
and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA 
GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH 
webpages it cannot be concluded that designations, logos, names and trademarks are free of commercial property rights. 

ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH. 

 

18 

Contact 

ESERA GmbH 
Adelindastrasse 20 
87600 Kaufbeuren 
GERMANY 
Tel.: +49 8341 999 80-0

 

Fax: +49 8341 999 80-10

 

www.esera.de

 

[email protected]

 

WEEE-Number: DE30249510

 

 
 

 
 

Содержание 11228 V2

Страница 1: ...the 8 fold digital output 8 8 and put the device into operation please read these operating instructions carefully through to the end especially the section referring on safety instructions 2 Product...

Страница 2: ...4 Technical data Switching channels 8 switching relay NO separate inputs per channel Switching voltage 10 250V DC or AC voltage Switching current Max 16A for 3 seconds 10A continuous current per outpu...

Страница 3: ...put 19 Relay 1 output 20 Relay 2 input 21 Relay 2 output 22 Relay 3 input 23 Relay 3 output 24 Relay 4 input 25 Relay 4 output 29 GND ground button input 30 Button 1 input 10 30VDC 31 Push button 2 in...

Страница 4: ...r off Several outputs can be switched in one cycle After a waiting time of approx 2 seconds the system automatically switches to normal operation mode the PWR LED lights up permanently again and the s...

Страница 5: ...push button interface is interrogated via edge interrogation 10 Software Control The 1 Wire interface of the 8 fold digital output 8 8 is controlled by standard commands for the device DS2408 The pus...

Страница 6: ...may only be operated at the specified voltages and ambient conditions The device is intended for installation inside a control cabinet as a stationary device 14 Disposal note Do not dispose of the de...

Страница 7: ...ar and normal wear and tear Customer claims for damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from un...

Отзывы: