Conformity 

EN 50090-2-2 
EN 61000-4-2, ESD 
EN 61000-4-3, HF 
EN 61000-4-4, Burst 
EN 61000-4-5, Surge 
EN 61000-6-1, fault-free operation 
EN 61000-6-3, stray radiations 
RoHS 
 

Operating mode, display and operation 

The module has two operating modes: Normal mode and manual mode. 
 

Normal operation: 

After commissioning, the device is in normal operation, which means that a switching 

command via the 1-wire interface is switched directly to the corresponding output relay. The corresponding output 
LED lights up.

 

 

Manual mode: 

By pressing the "MAN/Select" key for 2 seconds, the module switches to manual mode (manual 

mode). The "PWR" LED flashes as confirmation. 
Press the "MAN/Select" button briefly to select an output. The LEDs 1-8 light up for the selected output. Press the 
"ON/OFF" key to switch the selected output on or off. 
Several outputs can be switched in one cycle.  
After a waiting time of approx. 2 seconds, the system automatically switches to "normal operation" mode, the 
"PWR" LED lights up permanently again, and the selected outputs are activated. 
 

Delete "Manual mode": 

By pressing the "ON/OFF" key for 2 seconds, the outputs selected in manual mode are 

switched off. 
 

Display 

Description 

Function LED display 

LED 1-8 

Output 1-8 

-  LED lights up for 2 seconds to start the system 
-  Normal operation: LED indicator lights up when the output is 

active 

-  Manual operation: The "Select" button can be used to select the 

output that is switched on or off. 
 

LED PWR 

Power 

-  LED lights up 2 seconds to start the system 
-  LED indicator lights up when an output relay is active 
-  LED display flashes in manual mode 

 

LED Status 

Status display 
manual mode 

-  LED lights up for 2 seconds to start the system 
-  Status display of the selected output after transition to normal 

operation (relay on or off) 
 

 
 

Pushbutton  Description 

Function pushbutton 

MAN/Select 

Operating mode /  
channel selection 

The pushbutton has two functions 

-  Switch to manual mode (press for 2 seconds) 
-  Output selection (press briefly) 

 

ON/OFF 

Output 2 On/Off 

The pushbutton has two functions 

-  Selected output On - Off (press briefly) 
-  Delete all manual mode outputs (press for 2 seconds) 

 

 

 

 

Содержание 11228 V2

Страница 1: ...the 8 fold digital output 8 8 and put the device into operation please read these operating instructions carefully through to the end especially the section referring on safety instructions 2 Product...

Страница 2: ...4 Technical data Switching channels 8 switching relay NO separate inputs per channel Switching voltage 10 250V DC or AC voltage Switching current Max 16A for 3 seconds 10A continuous current per outpu...

Страница 3: ...put 19 Relay 1 output 20 Relay 2 input 21 Relay 2 output 22 Relay 3 input 23 Relay 3 output 24 Relay 4 input 25 Relay 4 output 29 GND ground button input 30 Button 1 input 10 30VDC 31 Push button 2 in...

Страница 4: ...r off Several outputs can be switched in one cycle After a waiting time of approx 2 seconds the system automatically switches to normal operation mode the PWR LED lights up permanently again and the s...

Страница 5: ...push button interface is interrogated via edge interrogation 10 Software Control The 1 Wire interface of the 8 fold digital output 8 8 is controlled by standard commands for the device DS2408 The pus...

Страница 6: ...may only be operated at the specified voltages and ambient conditions The device is intended for installation inside a control cabinet as a stationary device 14 Disposal note Do not dispose of the de...

Страница 7: ...ar and normal wear and tear Customer claims for damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from un...

Отзывы: