Auto-E-Connect® Support 

The ESERA 

Auto-E-Connect®

 1-Wire Plug and Play system will be used for the  

1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors 
and actuators on the 1-Wire bus. It is optimized for industrial applications and 
enables significant added value beyond the sensor and chip data. 
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable 
libraries and outputs fully formatted data. 
The Auto-E-Connect functionality will be available from mid 2020 via 1-Wire Controllers, 1-Wire Gateways and  
1-Wire ECO from ESERA available. 
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in 
the download area for this article in the ESERA Webshop. 
 

Technical data 

Switching channels:  

8, switching relay (NO), separate inputs per channel 

Switching voltage:  

10 - 250V DC or AC voltage 

Switching current:  

Max. 16A for 3 seconds, 10A continuous current per output for resistive load.  
For capacitive or inductive loads, appropriate additional circuits, e.g. spark quenching 
capacitors, must be provided.  
Minimum load 10mA per output 

Fuses: 

External back-up fuse with 16A recommended 

Data interface:  

1-wire bus (12V, data and ground),  

1-Wire device: 

 DS2408 interface (8-fold I/O) 

Operating voltage:  

12VDC (+/-10%)  

Current consumpt.12V:   idle state, no output relay active: approx. 10mA 
All outputs active:  

approx. 270mA 

Push-button interface:   8 digital inputs (binary input), pulse input, e.g. for push-button or motion detector (make 

contact) 
Pulse duration min. 60ms 
Input voltage 10-30VDC, max. 10mA per input, common ground. 
Inputs isolated from 1-Wire interface and power supply. 
The cable length between module and button is not critical, but should not exceed 30m.  

Connection:  

screw terminals (up to 2.5qmm cable cross-section) 

 

Ambient conditions 

Temperature, operation:  -20°C to +50°C  
Humidity: 

 

10 - 92% (non-condensing) 

Dimensions:  

 

100 x 90 x 70mm (WxHxD) 

Protection class: 

II 

Protection type: 

IP20 

Insulation strength:  

500VAC output to 1-Wire Bus, 250VAC output to output 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание 11228 V2

Страница 1: ...the 8 fold digital output 8 8 and put the device into operation please read these operating instructions carefully through to the end especially the section referring on safety instructions 2 Product...

Страница 2: ...4 Technical data Switching channels 8 switching relay NO separate inputs per channel Switching voltage 10 250V DC or AC voltage Switching current Max 16A for 3 seconds 10A continuous current per outpu...

Страница 3: ...put 19 Relay 1 output 20 Relay 2 input 21 Relay 2 output 22 Relay 3 input 23 Relay 3 output 24 Relay 4 input 25 Relay 4 output 29 GND ground button input 30 Button 1 input 10 30VDC 31 Push button 2 in...

Страница 4: ...r off Several outputs can be switched in one cycle After a waiting time of approx 2 seconds the system automatically switches to normal operation mode the PWR LED lights up permanently again and the s...

Страница 5: ...push button interface is interrogated via edge interrogation 10 Software Control The 1 Wire interface of the 8 fold digital output 8 8 is controlled by standard commands for the device DS2408 The pus...

Страница 6: ...may only be operated at the specified voltages and ambient conditions The device is intended for installation inside a control cabinet as a stationary device 14 Disposal note Do not dispose of the de...

Страница 7: ...ar and normal wear and tear Customer claims for damages for example for non performance fault in contracting breach of secondary contractual obligations consequential damages damages resulting from un...

Отзывы: