o

 

Automatic Positioning

: The device logs on to any ECO Controller with Auto-E-Connect III with the new 

request OWD number. This automatic login works up to the maximum possible OWD number of the 
ECO controller  

o

 

Sensorfinder Function

: The ECO Controller can activate a status LED within the ESERA 1-Wire Pro 

sensors. The status LED flashes or lights up permanently for a certain time. This makes the detection of 
a device in a 1-Wire network much easier. A faster detection saves a lot of time and therefore money 
when searching for a 1-Wire device. 

o

 

Classes Assignment

: ESERA 1-Wire devices are assigned to OWD classes with the same properties. 

This assignment enables fully automatic visualization and data evaluation in control systems. A class list 
is available from ESERA

.  

 

For further information about the ESERA Auto-E-Connect System please refer to the ESERA website and 
the ESERA Config Tool 3. 
Auto-E-Connect is registered as a German and European Patent by ESERA GmbH. 
 

Technical data 

Function 

Multisensor or temperature and rel.humidity 
Monitoring of the operating voltage  

Temperature sensor 

high-precision digital temperature sensor with 12-bit measured value 
resolution  

Measuring range 
temperature  

-40°C to +85°C (Sensor element: -40°C to +85°C) 

Accuracy temperature 

0,2° in the range 5 to 60°C (better than DS18B20 Sensor) 

Resolution 

12 bit, 0.06°C/bit depending on selected resolution   

Humidity sensor 

capacitive digital humidity sensor with high accuracy   

Measuring range humidity 

0-100% rel. humidity  

Accuracy humidity 

2% in the range of 20-80% at 25°C  

Data output 

0-10V corresponds to 0-100% relative humidity, 0.1V = 1% rH 

Interface 

3 - wire connection (data, ground and 5V, parasitic operation not 
supported) 

Connection 

screw terminal for cable solid 0.2 to 2.5qmm or  
fine stranded 0,2 to 1,5qmm 
for connection we recommend slotted screwdriver size 2,5x75 

1-Wire interface 

based on DS2438 

Operating voltage 

5 V= (+10%/-20%) 

Current consumption 

approx. 2mA 

Auto-E-Connect 

level I,II,  from 2022 level I-III 

 

Ambient conditions 

Protection system 

IP20 

Protection class 

III 

Temperature, operation 

-25°C to 80°C, (limitation by carrier system, sensor -40°C to +125°C)  

Humidity 

10 - 90% (non condensing) 

Dimensions (outside) 

71 x 71 x 32mm (LxWxH) 

 

 
 
 
 
 
 
 

Содержание 11150

Страница 1: ...onal temperature and humidity sensor for private schools public buildings and companies precise temperature and humidity sensor with 12Bit resolution universal on wall mounting stylish and high quality sensor housing easy voltage supply 5VDC Application Heating control control of individual rooms Control sensor for ventilation system Monitoring of living areas for risks of mould Note Before you st...

Страница 2: ...us system of the 1 Wire Multisensor Pro is carried out with screwless push in terminals and can be operated in standard mode 3 cables for ground data and 5V Each 1 Wire Multisensor Pro has an individual serial number 2 Auto E Connect Support With the launch of the ECO Controller the ESERA Auto E Connect 1 Wire Plug and Play system for the 1 Wire Bus is now introduced and supported This now enables...

Страница 3: ...bsite and the ESERA Config Tool 3 Auto E Connect is registered as a German and European Patent by ESERA GmbH 3 Technical data Function Multisensor or temperature and rel humidity Monitoring of the operating voltage Temperature sensor high precision digital temperature sensor with 12 bit measured value resolution Measuring range temperature 40 C to 85 C Sensor element 40 C to 85 C Accuracy temperat...

Страница 4: ...38 module Humidity To obtain the rel humidity in percent multiply the output value Vas by a factor of 10 0 1V corresponds to 1 relative humidity 7 Data output 1 Wire Controller 1 Wire Gateway For the 1 Wire Multisensor Pro the following measured values are calculated and output by the 1 Wire Controller 1 Wire Gateway The dew point calculation is a function of the 1 Wire Controller 1 Wire Gateway D...

Страница 5: ...t be observed during connection The Multi sensor must be connected with three cables ground 1 Wire Data and 5V Parasitic mode is not supported 13 Assembly The mounting location must be protected from direct sunlight moisture e g dripping water and drafts The device may only be used in dry indoor rooms and in protected outdoor areas During installation make sure that the ventilation openings are lo...

Страница 6: ...not dispose of the device within the household waste According to the directive concerning old electrical and electronic appliances electronic devices must be disposed of via the collecting points for old electronic appliances 17 Safety instructions When using products that come into contact with electrical voltage the valid VDE regulations must be observed especially VDE 0100 VDE 0550 0551 VDE 07...

Страница 7: ...nteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and...

Отзывы: