background image

 

 
 

Art. No. 11150  

 

 

 

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of 
ESERA GmbH. Errors and technical modification subject to change. 



ESERA GmbH 2021 

www.esera.de 

11150 V3.0 R1.0  Manual 

Page 5 of 7 

https://www.esera.de/kompatible-steuerungen-zentralen/loxone-integration/demo-1-wire-controller-1-loxone-
integration/

 

 

10 

Integration in FHEM 

For the integration into the open source automation software FHEM we provide a software module for 
reading in the 1-Wire Multisensor via 1-Wire Controller / 1-Wire Gateway. This means that evaluation scripts 
are no longer necessary. 
Details can be found on the ESERA website under "Compatible controllers - control units / FHEM integration

” 

https://www.esera.de/kompatible-steuerungen-zentralen/fhem-integration/

 

 

11 

Measurement accuracy 

The sensor elements inside the 1-Wire Multisensor Pro are calibrated. Please note that the measuring 
accuracy may possibly decrease towards the measuring range limits as well as at very high/low operating 
temperatures. 
 

12 

Connection 

The 1-Wire Multisensor Pro is connected by screw terminals. 
The connection terminal is intended for solid cables with 0.2 to 
2.5qmm or fine wire cables with 0.2 to 1.5qmm cross-section. 
For the connection we recommend slotted screwdriver size 
2,5x75. 
The pin assignment is printed on the circuit board.  
The correct polarity must be observed during connection. 
The Multi-sensor must be connected with three cables (ground, 
1-Wire Data and 5V). Parasitic mode is not supported. 
 
 
 
 

 

13 

Assembly 

The mounting location must be protected from direct sunlight, moisture (e.g. dripping water) and drafts. The 
device may only be used in dry indoor rooms and in protected outdoor areas. During installation, make sure 
that the ventilation openings are located at the top and bottom. Also note the imprint of the direction of the air 
flow on the connection side of the unit 
A draught-free location must be selected for installation. The unit is intended for installation inside a living 
room as a stationary unit. The 1-Wire Multisensor can be ideally mounted on a flush-mounted box through 
clever housing cut-outs. 
 

14 

1-Wire Network Cabling 

The special feature of the 1-Wire system is the "BUS technology". All devices (sensors and actuators) are 
operated in parallel on a three-wire line, which is used for both power supply and data communication. The 1-
Wire bus system joins the list of other successful bus systems such as CAN or Modbus RTU. All of the installation 
principles recommended for these are also applicable and appropriate to 1-Wire.  
The maximum size of a 1-Wire Network is determined by various factors. These are mainly:  

Note 

The module may only be operated at the voltages and under the ambient conditions intended for it. The 
operating position of the device is arbitrary. 
The modules may only be commissioned by a qualified electrician. 
 
For further information on the operating conditions, see the following instructions under 
"Operating conditions". 
 
 

Содержание 11150

Страница 1: ...onal temperature and humidity sensor for private schools public buildings and companies precise temperature and humidity sensor with 12Bit resolution universal on wall mounting stylish and high quality sensor housing easy voltage supply 5VDC Application Heating control control of individual rooms Control sensor for ventilation system Monitoring of living areas for risks of mould Note Before you st...

Страница 2: ...us system of the 1 Wire Multisensor Pro is carried out with screwless push in terminals and can be operated in standard mode 3 cables for ground data and 5V Each 1 Wire Multisensor Pro has an individual serial number 2 Auto E Connect Support With the launch of the ECO Controller the ESERA Auto E Connect 1 Wire Plug and Play system for the 1 Wire Bus is now introduced and supported This now enables...

Страница 3: ...bsite and the ESERA Config Tool 3 Auto E Connect is registered as a German and European Patent by ESERA GmbH 3 Technical data Function Multisensor or temperature and rel humidity Monitoring of the operating voltage Temperature sensor high precision digital temperature sensor with 12 bit measured value resolution Measuring range temperature 40 C to 85 C Sensor element 40 C to 85 C Accuracy temperat...

Страница 4: ...38 module Humidity To obtain the rel humidity in percent multiply the output value Vas by a factor of 10 0 1V corresponds to 1 relative humidity 7 Data output 1 Wire Controller 1 Wire Gateway For the 1 Wire Multisensor Pro the following measured values are calculated and output by the 1 Wire Controller 1 Wire Gateway The dew point calculation is a function of the 1 Wire Controller 1 Wire Gateway D...

Страница 5: ...t be observed during connection The Multi sensor must be connected with three cables ground 1 Wire Data and 5V Parasitic mode is not supported 13 Assembly The mounting location must be protected from direct sunlight moisture e g dripping water and drafts The device may only be used in dry indoor rooms and in protected outdoor areas During installation make sure that the ventilation openings are lo...

Страница 6: ...not dispose of the device within the household waste According to the directive concerning old electrical and electronic appliances electronic devices must be disposed of via the collecting points for old electronic appliances 17 Safety instructions When using products that come into contact with electrical voltage the valid VDE regulations must be observed especially VDE 0100 VDE 0550 0551 VDE 07...

Страница 7: ...nteed quality resulting from intent or gross negligence Claims made under the Product Liability Act are not affected If defects occur for which the ESERA GmbH is responsible and in the case of replacement goods the replacement is faulty the buyer has the right to have the original purchase price refunded or a reduction of the purchase price ESERA GmbH accepts liability neither for the constant and...

Отзывы: