Step 2.
Center Strut assembly between Bases at
required install location. With felt marker or other
means
Mark
location of Roof Attachment on the
roof.
Install
Roof Attachment per manufacturer
instructions.
Note:
Image shows roof markings at low edge of
module, process is the same for all MA installation
locations.
Tip:
Use off-center slots on the MA
Strut if roof obstructions prevent
the use of center slot.
ALERT:
See Sheet Title: Ballast Layout
–
XX in
the Racking Construction Set for installation
locations of Mechanical Attachments on
each individual project.
Roof markings
Torque Clip
Torque Clip is fitted over the pilot
holes on the Base. MA Strut is then
aligned with the Torque Clip and Pilot
hole before being secured by an M6
Bolt.