Firmware Update via DS 302-Objects
Manual • Doc.-No.: C.3010.21 / Rev. 3.1
CAN-CBX-DIO8
Seite 120 von 123
8.12.2 Download Control via Object 1F52
h
INDEX
1F52
h
Name
Verify Application Software
In this object the date and the time of the generation of the application software can be stored to
check later whether the configuration complies with the expected configuration or not.
Index
Sub-
index
Description
Value range
Default-
Value
Data type
Access
mode
1F52
h
0
number of entries
2
2
unsigned 8
ro
1
application_software_date
0...
FFFF FFFF
h
-
unsigned 32
ro
2
application_software_time
0...
FFFF FFFF
h
-
unsigned 32
ro
Meaning of the variables:
application_software_date Date of the last application software of the module, specified in days
since 01.01.1984.
Example: 0000 196D
h
-> 26.10.2001
application_software_time Time is the number of milliseconds since midnight of the day of the
generation of the last application software.
Example: 02A0 AB8E
h
-> approx. 12:14 pm