Hardware Installation
8.
Replace the PC cover.
Secure the cover with the according screws at the back of the PC.
9.
Connect the CAN wire.
Please note that the CAN bus has to be terminated at both ends!
esd
offers special T-
connectors and terminator connectors. Additionally the CAN_GND signal has to be
connected to earth at
exactly one
point. For easier wiring the termination connectors are
equipped with an earth connector (4.8 mm fast-on, male).
A CAN participant without an electrically isolated interface acts as an earth connection.
The CAN-PCI/405-B4 is equipped with a 37-pole DSUB panel connector (male) in the slot
bracket. Four CAN channels can be connected via the DSUB connector.
As accessory the cable CAN-PCI/405-B4-1C4 (see order information) is available.
10. Reconnect the power supply of the PC.
11. Switch on the PC, the peripheral devices and the other CAN participants in any order.
12. End of hardware installation.
Page 8 of 29
Hardware Manual • Doc. No.: C.2041.21 / Rev. 1.2
CAN-PCI/405-B4