11
Low Temperature BOD Incubator
3.3.3.2 Enter PIN
Step
Description
Button
Display
1
Press MENU or SET TEMP button to enter PIN.
MENU –
SET TEMP
2
Press UP/DOWN button to set the PIN’s digit. Press SET TEMP to confirm
the number and move to the next digit.
UP/DOWN –
SET TEMP
3
Repeat step 3 until the fourth digit.
-
3.3.4 Address Setting (1 – 32)
Step
Description
Button
Display
1
Press MENU button until the display shows Setting. Press SET TEMP to
enter the menu.
MENU –
SET TEMP
2
Press MENU button until the display shows Address.
MENU
3
Press UP/DOWN button to choose the address. Press SET TEMP to save
setting.
UP/DOWN –
SET TEMP
3.3.5 UV Lamp
There are 2 modes for UV lamp operation:
Manual-operation (UV)
o
UV lamp can be turned ON for sterilization during operation as required.
o
Period of UV lamp operation can be set and UV lamp is turned ON immediately after setting
is confirmed.
Auto-operation (UV1)
o
UV lamp is ON for 15 min automatically which is factory setting as equipment is turned on.
o
Period of UV lamp operation can be set and operates as per user’s request as the equipment
is turned OFF and ON again.
3.3.5.1 Manual operation UV lamp (0 – 60 minutes)
Step
Description
Button
Display
1
Press MENU button until the display shows Setting. Press SET TEMP to
enter the menu.
MENU –
SET TEMP
2
Press MENU button until the display shows UV.
MENU
3
Press UP/DOWN button to set the required UV timer. Press SET TEMP to
save setting.
UP/DOWN –
SET TEMP
Note:
UV LAMP Indicator will light up, indicating that the UV lamp in ON
Pressing the UP button twice during normal operation will show the remaining UV time
If the timer is re-set during operation, the timer will restart once the new setting is confirmed
3.3.5.2 Auto operation UV lamp (0 – 60 minutes)
Step
Description
Button
Display
1
Press MENU button until the display shows Setting. Press SET TEMP to
enter the menu.
MENU –
SET TEMP
2
Press MENU button until the display shows UV1.
MENU
3
Press UP/DOWN button to set the required UV1 timer. Press SET TEMP
to save setting.
UP/DOWN –
SET TEMP
Note:
UV1 will operate automatically every time the equipment is turned on
When restarted, the UV timer is assumed to set to 15 minutes
UV LAMP Indicator will light up, indicating that the UV lamp in ON
Pressing the UP button once during normal operation will show the remaining UV1 time
Содержание Isotherm IFC-110-8