![background image](http://html1.mh-extra.com/html/esco/cyclone-20380/cyclone-20380_instruction-manual_2426142004.webp)
1.800.352.9852 •
•
www.esco.net
4
OPERATING INSTRUCTIONS
1.
Always wear eyewear and hearing protection while operating bead seating tank.
2.
Keep work area clear.
3.
Lay mounted tire flat on ground or stand (optional) with wide flange up (inflating stem fac-
ing down) place stand under rim near inflating stem.
4.
Attached self holding chuck from air supply to inflating stem on rim.
5.
Hold bead seater at an approximately 45 degree angle (shown below) from floor with
guide on top of rim.
6.
Hold handle tight and quickly open discharge valve.
7.
Operating pressure of unit is 40
-
155 PSI from compressed air supply. Fill bead seating
tank to a minimum of 40 psi from air compressor. Increase pressure as necessary. The
safety pop
-
off is set at 165 psi (11.3 bar)
CYCLONE BEAD SEATING TANK—
5
GALLON #20380
Larger tires may be too difficult to seat, please make sure to use the proper sized Bead Seater for the Size Tire.
45
°
RECOMMENDED PRESSURE CHART
Tire Type
Pressure
ATV
40 PSI / 2.75 BAR
Passenger Car Radial Tire
60 PSI / 4.15 BAR
LT/SUV
80 PSI / 5.5 BAR
Truck and Bus Radial Tire
100 PSI / 6.9 BAR
OTR
120
-
155 PSI / 8.25
-
10.6 BAR
HANDLE
AIR PRESSURE
GAUGE
AIR TANK
AIR INTAKE
AIR RELEASE
VALVE HANDLE
GUIDE
PRESSURE
RELEASE VALVE
FLARRED
BARREL
OPTIONAL STAND
(AVAILABLE FROM MULTIPLE