26
8.2 OUTER FINGER REPLACEMENT
1. Take out all of the screws and remove the door trim.
2. Pull away only enough of the outer laminate to expose the damaged finger
stock.
3. Using a soldering iron, heat the solder to remove the damaged finger stock.
4. Scrape the area to remove any old solder.
5. Before attaching the new finger stock, wipe down the area with denatured
alcohol.
6. Apply flux to the new finger stock and the area to be soldered.
7. Align the new section of finger stock with the existing fingers and solder in
place.
8. Scrape away excess solder.
9. Replace the laminate and door trim.
8.3 INNER FINGER REPLACEMENT
1. Remove the necessary screws to loosen the galvanized shield in the area of
the damaged fingers.
2. Using a soldering iron, heat the solder to remove the damaged finger stock.
3. Scrape the area to remove old solder and wipe down with denatured alcohol.
4. Apply flux to the new finger stock and the area to be soldered.
5. Align the new section of finger stock with the existing fingers and solder in
place.
6. Scrape away excess solder.
7. Replace the galvanized shield.
Take care
to avoid
damaging the backing
foam and microwave
absorber, if included.