background image

7

Maintenance

Before installing any components, follow the safety information in the ETS-Lindgren 

Product     

Information Bulletin

 included with your shipment.

Disconnect the power before proceeding with recommended maintenance. Do not perform 
maintenance while the positioner is operating

 

 

 

Warranty may be void if the housing is opened.

 

 

 

If you have any questions concerning maintenance, contact ETS-Lindgren Customer Service.

Positioner Maintenance Recommendations 

Periodic Maintenance

Check cables for wear. Ensure they are clear of potential damage from moving parts.
Ensure bearing and pinion have adequate lubrication.

Replacement Parts

Following are the part numbers for ordering replacement parts for the 2301 Precision  
Positioner.

Part Description

Part Number

Laser

1723184

Fiber-Optic Cable

705347-10

Emergency Stop Switch Assembly  
(IEC inlet and IEC outlet power connections)

1719562

Service Procedures

For the steps to return a system or system component to ETS-Lindgren for service, see the 

Product Information 

Bulletin

 included with your shipment.

Safety Precautions

Removing top panel will expose AC power.

Do not use damaged or crimped AC power cords.

WARRANTY

Содержание ETS-LINDGREN 2301

Страница 1: ...2301 Positioner User Manual 1723531 Rev B January 2021...

Страница 2: ...does it convey any license under its patent rights nor the rights of others All trademarks are the property of their respective owners Copyright 2020 2021 by ETS Lindgren Inc All Rights Reserved No p...

Страница 3: ...ons 8 Physical Specifications 8 Electrical Specifications 8 Assembly and Installation 9 Pre Installation Tasks 9 Electrical Installation 10 Input Output Connections 11 Trigger 11 Reset 11 Fiber Optic...

Страница 4: ...uct Caution Denotes a hazard Failure to follow instructions could result in minor personal injury and or property damage Included text gives proper procedures Warning Denotes a hazard Failure to follo...

Страница 5: ...ive grounding conductor inside or outside the instrument or disconnection of the protective earth terminal could result in personal injury Warning HEAVY OBJECT Unassisted lifting can cause injury Mech...

Страница 6: ...an illuminated switch and the inlet for the customer s EUT is operated by a non illuminated switch Labels on the top surface of the motor base indicate the location of each inlet Standard Configuratio...

Страница 7: ...heck cables for wear Ensure they are clear of potential damage from moving parts Ensure bearing and pinion have adequate lubrication Replacement Parts Following are the part numbers for ordering repla...

Страница 8: ...out Base Station Mount 167 64 cm 66 0 in Height with Base Station Mount 213 11 cm 83 9 in Width 103 63 cm 40 8 in Depth 101 60 cm 40 0 in Overall Weight 90 72 kg 200 0 lb Maximum Load Capacity 24 95 k...

Страница 9: ...for aligning system Customer provides RF power and control cabling to the top of the unit and to the EUT 2 The center of rotation for the unit must intersect the line through the bore sight of the mea...

Страница 10: ...power source is appropriate for the wire gauge used and that the wire gauge is adequate for the motor load Using undersized wire gauge will result in a higher than expected voltage drop in the power...

Страница 11: ...0 Used in case the IP address of the device is unknown Fiber Optic The positioner is equipped with a fiber optic inlet and a fiber optic outlet Connect the positioner to the included Ethernet to fiber...

Страница 12: ...d COMMAND The backwards compatible Model 2090 Multi Device Controller command When used by itself controls the first device in a multi axis system and when arguments are required supports only a singl...

Страница 13: ...TS Lindgren Inc 2301 Precision Positioner Module Name PCA120518 FW N NN identifies this device as a 2301 Precision Positioner The Module Name parameter is a place holder to identify a specific module...

Страница 14: ...e Name parameter in the IDN query response is a place holder to identify a specific device in a network If you have more than one device you might want to identify them with different module names For...

Страница 15: ...e Command HOME Description The device has a mechanical home sensor Every time the positioner is turned on a home procedure must be performed so the current position is known by the firmware To home th...

Страница 16: ...pleted See Homing Procedure p 14 Example AXIS1 OPC Scan Command SCAN Description Instructs the positioner to begin scanning between preset lower and upper limits Example AXIS1 SCAN Seek Negative Comma...

Страница 17: ...nd lower counterclockwise limits Example AXIS2 SKP 90 Seek Relative Command SKR nnn n Description Instructs the device to begin seeking the specified target value relative to the current position The...

Страница 18: ...ample AXIS1 2 ST Trigger Configuration Command TRIGGER ON OFF step size reference pre trigger delay pulse length post trigger delay polarity Description Use this command to configure the trigger Where...

Страница 19: ...rection 5 Hardware Limit hit 6 Polarization limit violation 7 Lost communication 9 Encoder failure 10 Trigger failure 11 Motor overheat 12 Relay failure 13 Position out of bounds 32 Motor driver fault...

Страница 20: ...using the same IP address The IP address of the device will need to be changed if more than one device is in the same LAN To change the IP address of an ETS Lindgren Ethernet device use its embedded...

Страница 21: ...e the connection is working by typing IDN then pressing the Enter key on the keyboard The device will respond with an identification string such as the one shown below The IP address can be changed us...

Страница 22: ...22 Computer Network Configuration Connect to an ETS Lindgren Ethernet by setting the computer Ethernet interface to the selections shown below...

Страница 23: ...net cables It also communicates with the computer and allows it to access a network device Follow these steps on a Windows 10 PC to configure the Ethernet adapter 1 Ensure that the Ethernet adapter is...

Страница 24: ...ange Ethernet settings In the search results click change Ethernet settings In the Settings window click Change adapter options Right click on the Ethernet Adapter you intend to configure and select P...

Страница 25: ...192 168 0 1 Subnet mask 255 255 255 0 Default gateway blank Select Use the following DNS server addresses and leave Preferred and Alternate DNS server fields blank Then click OK Information about subn...

Страница 26: ......

Отзывы: