ESBE T4 Скачать руководство пользователя страница 7

7

Our other UFH products:

Single-loop Pump Pack

The single-loop assembly is designed to connect 

to new and existing heating systems with 15mm 

compression connections for the flow and return.
The temperature switch supplies power to the pump 

and will remain open until the existing heating 

system water is above 40°c. Following this, the 

switch will close activating the 'A' rated pump, which 

will allow the TMV to mix flow and return to the 

required UFH temperature. Unit is suitable for use 

with floor areas of 60–90sqm or max output of 5kW.

Heat Pump Pack

The heat pump model is a pre-assembled unit that 

is designed to be connected (via ball valves) to the 

manifold. The unit is for use in applications where 

water temperature controls are not required. 

This is typically seen where heat pumps or low 

temperature systems are utilised. 
The unit includes an ‘A’ rated energy efficient pump 

and is suitable for use with floor areas up to 250sqm 

or a maximum output of 20kW. Primary flow and 

return connections can be made from the side or 

the bottom of the unit. This can also be mounted on 

either the left- or right-hand side of the manifold.

7

Содержание T4

Страница 1: ...For underfloor heating with thermostatic mixing valve ESBE T4 Pump Control Set Installation and Commissioning Manual ...

Страница 2: ...le swivel joints for fast connection to 1 Female manifold tappings Nickel plated for improved appearance In built non return valve in flow elbow to enable simple system filling when commissioning 3 4 Female BSP flow and return connections Suitable for any manifold with connections on 210mm centres Also available in 200 and 225mm Fully reversible offering with side or bottom entry primary connectio...

Страница 3: ...imary connections can be applied from the side or bottom of the control pack 2 Connections Dimensions 3 Technical Data Maximum static pressure 10 Bar Maximum differential pressure 3 Bar Maximum temperature 95 C Operating temperature range Adjustable between 20 C to 55 C BS2164 Inlet connections 2 x 3 4 BSPF Outlet connections 2 x 1 BSPM swivel joint Overall dimensions mm 290 h x 150 w x 140 h Excl...

Страница 4: ... 4 Pipe connection orientation can be altered to suit using flow return elbow 3 supplied loose fitted in either flow or return 5 5 A swivel joint is fitted to each side of the control group for connecting to the 1 F manifold tappings Carefully offer up and screw the swivel joint threads evenly into the manifold using a 37mm A F spanner the use of a 31mm A F spanner will also ensure that the connec...

Страница 5: ...en select the desired pump setting The ESBE T4 control pack comes pre assembled ready for installation please ensure the pump connections are tightened before commissioning These connections are equipped with EPDM seals 7 Pump Settings Buttons All pump functions can be controlled with two buttons The button switches the night reduction function on and off The button controls the operating modes Th...

Страница 6: ...ure it against neing switched on again by unauthorized persons At high water temperatures and system pressures wait for the pump to cool down beforehand There is risk of burns Control panel and LED display 1 Display of energy consumption in watts 2 Automatic night reduction display 3 Button for activating the automatic night reduction 4 Operating mode selection button 5 Display for activated AUTO ...

Страница 7: ...t is suitable for use with floor areas of 60 90sqm or max output of 5kW Heat Pump Pack The heat pump model is a pre assembled unit that is designed to be connected via ball valves to the manifold The unit is for use in applications where water temperature controls are not required This is typically seen where heat pumps or low temperature systems are utilised The unit includes an A rated energy ef...

Страница 8: ......

Отзывы: