1. General 

1.1

  Provides control of flow and return water temperature in an underfloor heating  

 

 

system. Pre-assembled and tested to ensure that it can be fitted with minimum 

 

 

on-site labour required and commissioned immediately once fitted. 

1.2

  Designed to connect to the right-hand side of a manifold with 200mm as standard  

 

 

(210 / 225mm optional) between the centres of the flow and return arms. The control   

 

group can also be altered to fit to the left-hand side of a manifold simply by turning the  

 

control group elbows through 180 degrees, using the union fittings at the top and  

 

 

bottom of the pump. The pump motor may need to be rotated through 180 degrees to  

 

minimise the space occupied by the control group. Primary connections can be applied  

 

from the side or bottom of the control pack.

2. Connections & Dimensions

3. Technical Data

Maximum static pressure                 10 Bar

Maximum differential pressure      3 Bar

Maximum temperature                    95°C
Operating temperature range        Adjustable between 20°C to 55°C (BS2164)
Inlet connections                               2 x 3/4" BSPF 
Outlet connections                           2 x 1" BSPM swivel joint
Overall dimensions (mm)                290 h x 150 w x 140 h (Excluding item.3) 
Kvs                                                         3.4
Material 

Nickel plated brass 

Power 18kW

Item

Description

Qty

1

Stuart Turner 25/6 Pump

1

2

ESBE Thermostatic Mixing Valve

1

3

Flow / Return Elbow

1

4

2mm Rubber Washer

2

5

1 1/2” Rapid Connection Nut

2

6

Elbow Flanged

1

7

3/4” Female BSP Flow and Return

2

8

3/8” Pocket

1

9

Temperature Gauge

1

10

Manifold Centre Distance Spacer

1

R

Return from Manifold / Flow to Heat 

Source

NA

H

Flow from Heat Source

NA

282

70

156

200*

1”M BSP

3/4”F BSP

*STANDARD CENTRE DISTANCE. 210MM & 225MM ALSO AVAILABLE

Содержание T4

Страница 1: ...For underfloor heating with thermostatic mixing valve ESBE T4 Pump Control Set Installation and Commissioning Manual ...

Страница 2: ...le swivel joints for fast connection to 1 Female manifold tappings Nickel plated for improved appearance In built non return valve in flow elbow to enable simple system filling when commissioning 3 4 Female BSP flow and return connections Suitable for any manifold with connections on 210mm centres Also available in 200 and 225mm Fully reversible offering with side or bottom entry primary connectio...

Страница 3: ...imary connections can be applied from the side or bottom of the control pack 2 Connections Dimensions 3 Technical Data Maximum static pressure 10 Bar Maximum differential pressure 3 Bar Maximum temperature 95 C Operating temperature range Adjustable between 20 C to 55 C BS2164 Inlet connections 2 x 3 4 BSPF Outlet connections 2 x 1 BSPM swivel joint Overall dimensions mm 290 h x 150 w x 140 h Excl...

Страница 4: ... 4 Pipe connection orientation can be altered to suit using flow return elbow 3 supplied loose fitted in either flow or return 5 5 A swivel joint is fitted to each side of the control group for connecting to the 1 F manifold tappings Carefully offer up and screw the swivel joint threads evenly into the manifold using a 37mm A F spanner the use of a 31mm A F spanner will also ensure that the connec...

Страница 5: ...en select the desired pump setting The ESBE T4 control pack comes pre assembled ready for installation please ensure the pump connections are tightened before commissioning These connections are equipped with EPDM seals 7 Pump Settings Buttons All pump functions can be controlled with two buttons The button switches the night reduction function on and off The button controls the operating modes Th...

Страница 6: ...ure it against neing switched on again by unauthorized persons At high water temperatures and system pressures wait for the pump to cool down beforehand There is risk of burns Control panel and LED display 1 Display of energy consumption in watts 2 Automatic night reduction display 3 Button for activating the automatic night reduction 4 Operating mode selection button 5 Display for activated AUTO ...

Страница 7: ...t is suitable for use with floor areas of 60 90sqm or max output of 5kW Heat Pump Pack The heat pump model is a pre assembled unit that is designed to be connected via ball valves to the manifold The unit is for use in applications where water temperature controls are not required This is typically seen where heat pumps or low temperature systems are utilised The unit includes an A rated energy ef...

Страница 8: ......

Отзывы: