Primary power supply
Make sure that the power source is connected to the correct supply voltage and that
it is protected by the correct fuse rating. A protective earth connection must be made
in accordance with regulations.
Rating plate with supply
connection data
WARNING
Make sure the power source is switched off before removing the fuse.
Recommended fuse sizes and minimum cable area
Powercut 400
Mains voltage
110 V 1~
230 V 1~
Mains cable area
3G2.5
3G2.5
Phase current
I
1eff
16 A
9 A
Fuse, anti-surge
32 A
16 A
NOTE!
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the power source in accordance with the relevant national regulations.
Supply from power generators
The power source can be supplied from different types of generators. However,
some generators may not provide sufficient power for cutting. Generators with AVR,
equivalent or better type of regulation with a min rated power of 6 kW are
recommended to supply the power source within it's full capacity.
Start with generator:
1) Start the generator
2) Turn on the power source by mains switch ON
Stop with generator
3) Turn off the power source by mains switch OFF
4) Stop the generator
GB
Содержание PowerCut 400
Страница 1: ...GB Valid for serial no 145 xxx xxxx 0463 277 001 GB 20121125 PowerCut 400 PT 39 Instruction manual ...
Страница 2: ... 2 ...
Страница 3: ... 3 ...
Страница 4: ... 4 ...
Страница 24: ... ESAB AB 2012 Diagram 24 bp28diag ...
Страница 25: ... ESAB AB 2012 25 bp28diag ...
Страница 26: ... ESAB AB 2012 26 bp28app2 Stainless Steel and Aluminium Cut Speeds Carbon Steel Cut Speeds ...
Страница 29: ... 29 notes NOTES ...