Recommended fuse sizes and minimum cable areas
Mig 410
3
50 Hz
3
50/60 Hz
3
50 Hz
3
60 Hz
3
60 Hz
Voltage V
230
400/415
500
230
440/460
Current A
at 100% duty cycle
28
16
13
28
14
at 60% duty cycle
42
24
19
41
21
at 50% duty cycle
45
28
20
45
22
Cable area mm
2
4 x 6
4 x 2.5
4 x 2.5
4 x 6
4 x 2.5
Fuse, slow A
25
20
20
25
20
Mig 510
3
50 Hz
3
50/60 Hz
3
50 Hz
3
60 Hz
3
60 Hz
Voltage V
230
400/415
500
230
440/460
Current A
at 100% duty cycle
43
25
20
43
23
at 60% duty cycle
68
39
31
68
35
Cable area mm
2
4 x 16
4 x 6
4 x 6
4 x 16
4 x 6
Fuse, slow A
63
35
35
63
25
NB:
The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
US
Содержание Origo Mig 410
Страница 46: ... 46 p ...
Страница 47: ... ESAB AB 2011 Nettoyage Limpieza Cleaning 47 ba52clean ...
Страница 48: ... ESAB AB 2011 Schéma Esquema Schematic diagram 48 ba58ea Mig 410 230 500V ...
Страница 49: ... ESAB AB 2011 49 ba58ea Mig 410 230 500V ...
Страница 50: ... ESAB AB 2011 50 ba58ea Mig 510 230 500 V ...
Страница 51: ... ESAB AB 2011 51 ba58ea Mig 510 230 500 V ...
Страница 52: ... ESAB AB 2011 Instructions de branchement Instrucciones de conexión Connection instruction 52 ba58c Mig 410 ...
Страница 53: ... ESAB AB 2011 53 ba58c Mig 510 ...
Страница 57: ... 57 notes NOTES ...