background image

-- 15 --

fhc1a1ea

6

ACCESSORIES

ESABFeed 30--4 M12

ESABFeed 30--4 M13

ESABFeed 30--4 M14

ESABFeed 48--4 M12

ESABFeed 48--4 M13

ESABFeed 48--4 M14

AristoFeed

with adapter

Control cable
23--p
0457 360 880

x

x

x

MEK 4

MEK 4SP

MEK 4C

MEK 44C

MED 44A

Control cable 23--p
0457 360 880

x

x

x

x

x

Cable kit,
remote control socket
23--p
0457 462 880

x

x

x

x

x

MEH 30

MEH 44

MED44B

MEK 2

Universal

Control cable 4--p, 12--p
0457 360 883

x

x

Cable kit
0443 341 880

x

x

x

x

Control cable 4--p
0457 360 882

x

x

Control cable
0457 360 881

x

Transformer
0457 467 880

x

Welding screen

0457 463 880

Bracket for water--cooled PSF

0457 357 251

7

ORDERING OF SPARE PARTS

Miggytrac 1001 is designed and tested in accordance with the international and Euro-
pean standards IEC/EN 60204--1, ISO/EN 12100--2 and IEC/EN 60974--10 .
It is the obligation of the service unit which has carried out the service or repair work
to make sure that the product still conforms to the said standard.

Spare parts are ordered through your nearest ESAB representative, see back cover.
When ordering spare parts, please state machine type and number as well as desig-
nation and spare part number as shown in the spare parts list on page 19.
This will simplify dispatch and ensure you get the right part.

GB

Содержание Miggytrac 1001

Страница 1: ...GB Valid for serial no 0536 0449 476 001 GB 2011 08 16 Miggytrac 1001 Instruction manual...

Страница 2: ...iggytrac 1001 from serial number 0536 2005 w 36 complies with standard EN 12100 2 and EN 60204 1 in accordance with the requirements of directive 98 37 EEC and with standard EN 61000 6 2 and also EN 6...

Страница 3: ...al data 7 3 INSTALLATION 8 3 1 General 8 3 2 Other connections 9 4 OPERATION 13 4 1 General 13 4 2 Start stop of carriage 13 4 3 Welding 13 4 4 Magnet 13 5 MAINTENANCE 14 5 1 General 14 5 2 Daily 14 5...

Страница 4: ...n S location of emergency stops S its function S relevant safety precautions S welding 2 The operator must ensure that S no unauthorised person is stationed within the working area of the equipment wh...

Страница 5: ...is safe FUMES AND GASES Can be dangerous to health S Keep your head out of the fumes S Use ventilation extraction at the arc or both to take fumes and gases away from your breathing zone and the gene...

Страница 6: ...able No external power is necessary Miggytrac 1001 is a small compact motor driven carriage on which an ESAB standard welding gun can easily be fitted The four driving wheels together with a powerful...

Страница 7: ...ly voltage 36 46 VAC Power 20 W Welding speed 150 1200 mm min Dimensions l x w x h 266x257x261 mm Weight 7 kg Slide adjustment 20 mm Remote control socket Volt and ampere wire feed Max values remote c...

Страница 8: ...ed units please contact your nearest ESAB retailer In the case of welding at a great distance from the feed unit an intermediate wire feed unit MEK 25 can be connected Miggytrac 1001 can also be power...

Страница 9: ...e feed unit is necessary ESABFeed 30 2 with control panel M11 Miggytrac 1001 cannot be connected to this feed unit ESABFeed 30 4 och 48 4 with M12 control panel It is not possible to adjust the voltag...

Страница 10: ...ticker 1 S Mount the switch with the cabling 2 S Open the socket for remote control connection 3 S Fit the cabling 4 S Fit the remote control socket on the front panel 5 S Connect the cabling with the...

Страница 11: ...ote control connection 2 S Fit the cabling 3 S Fit the remote control socket on the front panel 4 S Mount the switch with the cabling on the printed circuit board 5 S Connect the cabling with the prin...

Страница 12: ...nnecting Miggytrac 1001 to other feed units use the transformer and the control cable you find under Accessories on page 15 10 kohm F G Start Stop function J Reference K Reference welding voltage L Re...

Страница 13: ...tion between the drive wheels and the foundation increases resulting in a more stable carraiage despite its low weight The magnet is switched On Off using a twist grip on top of the chassis 4 2 Start...

Страница 14: ...to rectify any faults on the machine during the warranty period 5 2 Daily S Check that all cables and plugs are in good condition S Switch off the magnet and clean the bottom of the carriage S Clean...

Страница 15: ...er 0457 467 880 x Welding screen 0457 463 880 Bracket for water cooled PSF 0457 357 251 7 ORDERING OF SPARE PARTS Miggytrac 1001 is designed and tested in accordance with the international and Euro pe...

Страница 16: ...Dimension drawing 16 fhc1dim...

Страница 17: ...Diagram SW1 SW2 17 fhc1diag...

Страница 18: ...18 sida...

Страница 19: ...Spare parts list 19 spare Edition 2011 08 16...

Страница 20: ...otentiometer knob 10 0457357241 Vertical slide house 11 0398145808 Intermediate bracket 12 0417855009 Lever 13 0457357272 Knob slides 14 0457357130 Magnetic lifting device 15 0457357003 Chassis 1001 1...

Страница 21: ...21 miggy1001...

Страница 22: ...1 50 92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Ai...

Отзывы: