8 FAULT-TRACING / TROUBLESHOOTING
Try these recommended checks and inspections before sending for an authorized
service technician.
ELECTRIC SHOCK CAN KILL! Be sure that all primary power to the machine has
been externally disconnected.Open the line (wall) disconnect switch or circuit
breaker before attempting inspection or work inside of the power source.
Check the problem against the symptoms in the following troubleshooting guide. The remedy may be quite
simple. If the cause cannot be quickly located, shut off the input power, open up the unit, and perform a
simple visual inspection of all the components and wiring. Check for secure terminal connections, loose or
burned wiring or components, bulged or leaking capacitors, or any other sign of damage or discoloration.
Those indications do not invalidate all other safety regulations and restrictions expressed in other sections
of this manual.
Voltages in plasma cutting equipment are high enough to cause serious injury or possibly death.
Be particularly careful around equipment when the covers are removed.
NOTE
Before checking voltages in the circuit, disconnect the power from the high frequency generator to avoid
damaging your voltmeter.
8.1 TROUBLESHOOTING GUIDE
Any remedy that requires an intervention inside the machine must be executed by
an authorized service center.
A. Difficult Starting.
Change electrode
Change nozzle
Check for good, clean connection of work lead to workpiece
Check air pressure (5 - 5,5 bar)
Check torch power cable for continuity
Depress torch switch. After 2 seconds, is high frequency present?
No
Yes
Is the Air LED light on?
Repair/replace HF PCB
Yes
No
Repair/replace
Repair/replace
Control
power source
control PCB
Flow Switch
12
GB