6 CONTROL PANEL
0447 209 001
- 23 -
© ESAB AB 2022
2T NORMAL/PULSE TIG
In 2T normal pulse TIG mode, press the TIG torch trigger switch (1) to start the shielding gas flow and
initiate the arc. The current goes to start pulse for 20 ms then goes to initial current, then slopes up to
set current, the current changs between set current and background current. Release the trigger
switch (2) to start to slope down the current and terminate the arc. The shielding gas will continue to
flow in order to protect the weld and the tungsten electrode.
4T LATCH/PULSE TIG
In 4T latch/PULSE TIG mode, press the TIG torch trigger switch (1) to start the shielding gas flow and
initiate the arc. The current goes to start pulse for 20 ms then goes to initial current. Release the
Содержание Fabricator ES 410iC
Страница 2: ......
Страница 15: ...4 INSTALLATION 0447 209 001 15 ESAB AB 2022 e Reattach the side panel of the power source with the screws...
Страница 19: ...6 CONTROL PANEL 0447 209 001 19 ESAB AB 2022 6 CONTROL PANEL 6 1 Fabricator ET 410iP...