4 INSTALLATION
0447 209 001
- 13 -
© ESAB AB 2022
4.4
Recommended fuse sizes and minimum cable
area
Fabricator ES 410iC
Mains voltage
400 V ±15%, 3~50/60 Hz
Mains cable area
4×4 mm
2
Maximal current rating I
max
MMA
31 A
I
1eff
MMA
24 A
Fuse
Anti-surge
Type-C MCB
32 A
32 A
Maximum recommended extension cord
length
100 m/330 ft.
Minimum recommended extension cord size
4×6 mm
2
Supply from power generators
The power source can be supplied from different types of generators. However, some generators may
not provide sufficient power for the welding power source to operate correctly. Generators with
Automatic Voltage Regulation (AVR) or with equivalent or better type of regulation, with rated power 30
kW, are recommended.
4.5
Connect with Cool 2 using adaptor
Make sure the power source is turned off.
1. Connect the Cool 2 (0465 427 880) with the Cool 2 Adaptor (0447 248 001):
a. Pull the cable out of the cooling unit through the adaptor.
b. Set the adaptor on the cooling unit.
c. Connect the adaptor to the cooling unit by the provided M6×10 screws.
2. Connect the Cool 2 Adaptor to the Fabricator ET 410iP:
a. Remove the feet from the power source and install on the cooling unit.