![ESAB Fabricator EM 400i Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/esab/fabricator-em-400i/fabricator-em-400i_instruction-manual_2425010021.webp)
7 TROUBLESHOOTING
0446 404 001
- 21 -
© ESAB AB 2020
7
TROUBLESHOOTING
Perform these checks and inspections before sending for an authorised service technician.
Welder Error Codes and Solutions
Shows the screens
The following table describes the welder error code, as well as the causes and solutions
Error
Code
Displayed Content
Fault
Cause
Solution
Left
display
Right
display
F00
F00
None
Power-on self-test
E1
E1
None
Welding torch fault When the
equipment is
turned on, the
welding torch
trigger switch is on.
the switch may be
faulty.
Turn off the switch.
Replace the
welding torch.
E2
E2
None
Output terminal
over-temperature
The OKC terminal
and welding cable
is not connected
properly. The
copper
cross-sectional
area of the output
power cable is too
small. The output
cable OKC fails to
meet the
specification
requirement. The
fan does not work
or slows down.
Verify the OKC
terminal and
welding cable is
connected properly.
Use cables with
correct
cross-sectional
areas. Select
suitable cable
OKC. Verify that
the fan blades are
not stuck with any
foreign objects.