ESAB FABRICATOR 141i
Manual 0-5448 3-5 SAFETY AND INSTALLATION
50 / 60 Hz Single Phase Supply
Supply Voltage
115V AC
Input Current at Maximum Output
28.4 Amps
Maximum Recommended Fuse* or Circuit Breaker Rating
*Time Delay Fuse, UL class RK5. Refer to UL248
Maximum Recommended Fuse^ or Circuit Breaker Rating
^Normal Operating , UL class K5. Refer to UL248
30 Amps
30 Amps
Single Phase Generator Requirement
5 KW
Minimum Recommended Input Cable Size
12AWG
Maximum Recommended Input Cable Length
10ft (3m)
Minimum Recommended Grounding Cable Size
12AWG
Table 3-2: Electrical Service Guide
NOTE!
Welding arc outs may be experienced if an extension cord is used when STICK welding when operating the
Power Source on 95 VAC due to the lack of DC voltage at the STICK electrode.
Input Power
Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned on, the inrush circuit provides pre-charging for the
input capacitors. A relay in the Main PCB1 will turn on after the input capacitors have charged to operating voltage (after approximately
5 seconds)
NOTE!
Damage to the
Main PCB1
could occur if 140V AC or higher is applied to the Primary Power Cord.
Model
Primary Supply
Cord Size
(Factory Fitted)
Minimum Primary
Current Circuit Size
(Vin/Amps)
Current & Duty Cycle
MIG (GMAW/
FCAW)
STICK (SMAW)
LIFT TIG
(GTAW)
Fabricator
141i
12AWG (3.3mm
2
)
115V/20A
90A@20%
80A@35%
100A@20%
10AWG (5mm
2
)
115V/30A
140A@15%
90A@15%
140A@15%
Table 3-3: Primary Circuit Sizes to Achieve Maximum Current
3.07 Electromagnetic Compatibility
WARNING
Extra precautions for Electromagnetic Compatibility may be required when this Welding Power Source is
used in a domestic situation.
A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If elec-
tromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the
situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing
the welding circuit, see NOTE below. In other cases it could involve constructing an electromagnetic screen enclosing the
Welding Power Source and the work, complete with associated input filters. In all cases, electromagnetic disturbances shall
be reduced to the point where they are no longer troublesome.
Содержание fabricator 141i
Страница 19: ...ESAB FABRICATOR 141i Manual 0 5448 3 9 SAFETY AND INSTALLATION Notes...
Страница 20: ...ESAB FABRICATOR 141i SAFETY AND INSTALLATION 3 10 Manual 0 5448 This Page Intentionallly Blank...
Страница 40: ...ESAB FABRICATOR 141i OPERATION 4 20 Manual 0 5448 This Page Intentionally Blank...
Страница 42: ...ESAB FABRICATOR 141i THEORY OF OPERATION 5 2 Manual 0 5448 Notes...
Страница 70: ...ESAB FABRICATOR 141i DISASSEMBLY PROCEDURE 7 4 Manual 0 5448 2 3 4 Art A 12181...
Страница 79: ...ESAB FABRICATOR 141i Manual 0 5448 8 5 ASSEMBLY PROCEDURES Art A 12184 6 5 4 3 2 7 8 9 10 11 12 13 14...
Страница 81: ...ESAB FABRICATOR 141i Manual 0 5448 8 7 ASSEMBLY PROCEDURES Notes...
Страница 82: ...ESAB FABRICATOR 141i ASSEMBLY PROCEDURES 8 8 Manual 0 5448 Notes...
Страница 84: ...ESAB FABRICATOR 141i KEY SPARE PARTS 9 2 Manual 0 5448 9 02 Power Source Art A 11811_AB Figure 9 2 31...
Страница 88: ...ESAB FABRICATOR 141i KEY SPARE PARTS 9 6 Manual 0 5448 Notes...
Страница 91: ......