3 TECHNICAL DATA
0463 416 001
- 9 -
© ESAB AB 2017
3
TECHNICAL DATA
ET 300i (0445 100 900), ET 300iP (0445 100 920)
Mains voltage
230–480 V ±10%,
3~ 50/60 Hz
230 V ±10%, 1~ 50/60 Hz
Mains supply S
sc min
4.1 MVA
No demand
Z
max
0.04 Ohm
No demand
Primary current
I
max
MMA
30.0 A
29.0 A
I
max
TIG
22.0 A
20.0 A
No-load power
demand when in the energy-saving mode
U
in
230 V
63 W
74 W
U
in
400 V
68 W
U
in
480 V
72 W
Setting range
MMA
5 A / 20 V - 300 A / 32 V
5 A / 20 V - 200 A / 28 V
TIG
5 A / 10 V - 300 A / 22 V
5 A / 10 V - 200 A / 18 V
Permissible load at MMA
40% duty cycle
300 A / 32.0 V
60% duty cycle
250 A / 30.0 V
100% duty cycle
200 A / 28.0 V
200 A / 28.0 V
Permissible load at TIG
40% duty cycle
300 A / 22.0 V
60% duty cycle
250 A / 20.0 V
100% duty cycle
200 A / 18.0 V
200 A / 18.0 V
Power factor
at maximum current
TIG
0.96
0.98
MMA
0.96
0.99
Apparent power I
2
at
maximum current
11.6 kVA
6.6 kVA
Active power I
2
at maximum
current
11.2 kW
6.6 kW
Efficiency
at maximum current
TIG
83%
83%
MMA
86%
86%
Open-circuit voltage U
0
max
48 V
48 V
Open-circuit voltage U
0
max
with VRD 35 V activated
34 V
34 V
U
PK
12.4 kV
12.4 kV
Operating temperature
-10 to +40 °C (+14 to +104 °F)