6 CONTROL PANEL
0463 416 001
- 29 -
© ESAB AB 2017
A = Gas pre flow
E = Set current
B = Slope up
F = Remote min current
C = Slope down
G = Current range adjustable by the foot
pedal
D = Gas post flow
Foot pedal with 4-stroke using TIG torch trigger
In 4-stroke mode, with the foot pedal activated, press the TIG torch trigger switch (1) to start
the shielding gas flow and initiate the arc at a pilot level. Release the trigger switch (2) to
slope up the current to the remote min current. Use the foot pedal to adjust the current
between the remote min current and the set current value. To stop the welding, press the
trigger switch again (3). The current will slope down to the pilot level again. Release the
trigger switch (4) to terminate the arc. The shielding gas will continue to flow in order to
protect the weld and the tungsten electrode.
A = Gas pre flow
E = Set current
B = Slope up
F = Remote min current
C = Slope down
G = Current range adjustable by the foot
pedal
D = Gas post flow
Foot pedal
Press down the foot pedal (1) to start the shielding gas flow and initiate the arc. The current
slopes up to the set remote min current. Use the foot pedal to adjust the current between the
remote min current and the set current value. Release the foot pedal to start to slope down
the current and to terminate the arc. The shielding gas will continue to flow in order to protect
the weld and the tungsten electrode.