ESAB ES 300i Скачать руководство пользователя страница 44

ESAB subsidiaries and representative offices

www.esab.com

Europe

AUSTRIA

ESAB Ges.m.b.H

Vienna-Liesing

Tel: +43 1 888 25 11

Fax: +43 1 888 25 11 85

BELGIUM

S.A. ESAB N.V.

Heist-op-den-Berg

Tel: +32 15 25 79 30

Fax: +32 15 25 79 44

BULGARIA

ESAB Kft Representative Office

Sofia

Tel: +359 2 974 42 88

Fax: +359 2 974 42 88

THE CZECH REPUBLIC

ESAB VAMBERK s.r.o.

Vamberk

Tel: +420 2 819 40 885

Fax: +420 2 819 40 120

DENMARK

Aktieselskabet ESAB

Herlev

Tel: +45 36 30 01 11

Fax: +45 36 30 40 03

FINLAND

ESAB Oy

Helsinki

Tel: +358 9 547 761

Fax: +358 9 547 77 71

GREAT BRITAIN

ESAB Group (UK) Ltd

Waltham Cross

Tel: +44 1992 76 85 15

Fax: +44 1992 71 58 03

ESAB Automation Ltd

Andover

Tel: +44 1264 33 22 33

Fax: +44 1264 33 20 74

FRANCE

ESAB France S.A.

Cergy Pontoise

Tel: +33 1 30 75 55 00

Fax: +33 1 30 75 55 24

GERMANY

ESAB Welding & Cutting GmbH

Langenfeld

Tel: +49 2173 3945-0

Fax: +49 2173 3945-218

HUNGARY

ESAB Kft

Budapest

Tel: +36 1 20 44 182

Fax: +36 1 20 44 186

ITALY

ESAB Saldatura S.p.A.

Bareggio (Mi)

Tel: +39 02 97 96 8.1

Fax: +39 02 97 96 87 01

THE NETHERLANDS

ESAB Nederland B.V.

Amersfoort

Tel: +31 33 422 35 55

Fax: +31 33 422 35 44

NORWAY

AS ESAB

Larvik

Tel: +47 33 12 10 00

Fax: +47 33 11 52 03

POLAND

ESAB Sp.zo.o.

Katowice

Tel: +48 32 351 11 00

Fax: +48 32 351 11 20

PORTUGAL

ESAB Lda

Lisbon

Tel: +351 8 310 960

Fax: +351 1 859 1277

ROMANIA

ESAB Romania Trading SRL

Bucharest

Tel: +40 316 900 600

Fax: +40 316 900 601

RUSSIA

LLC ESAB

Moscow

Tel: +7 (495) 663 20 08

Fax: +7 (495) 663 20 09

SLOVAKIA

ESAB Slovakia s.r.o.

Bratislava

Tel: +421 7 44 88 24 26

Fax: +421 7 44 88 87 41

SPAIN

ESAB Ibérica S.A.

San Fernando de Henares

(MADRID)

Tel: +34 91 878 3600

Fax: +34 91 802 3461

SWEDEN

ESAB Sverige AB

Gothenburg

Tel: +46 31 50 95 00

Fax: +46 31 50 92 22

ESAB International AB

Gothenburg

Tel: +46 31 50 90 00

Fax: +46 31 50 93 60

SWITZERLAND

ESAB Europe GmbH

Baar

Tel: +41 1 741 25 25

Fax: +41 1 740 30 55

UKRAINE

ESAB Ukraine LLC

Kiev

Tel: +38 (044) 501 23 24

Fax: +38 (044) 575 21 88

North and South America

ARGENTINA

CONARCO

Buenos Aires

Tel: +54 11 4 753 4039

Fax: +54 11 4 753 6313

BRAZIL

ESAB S.A.

Contagem-MG

Tel: +55 31 2191 4333

Fax: +55 31 2191 4440

CANADA

ESAB Group Canada Inc.

Missisauga, Ontario

Tel: +1 905 670 0220

Fax: +1 905 670 4879

MEXICO

ESAB Mexico S.A.

Monterrey

Tel: +52 8 350 5959

Fax: +52 8 350 7554

USA

ESAB Welding & Cutting

Products

Florence, SC

Tel: +1 843 669 4411

Fax: +1 843 664 5748

Asia/Pacific

AUSTRALIA

ESAB South Pacific

Archerfield BC QLD 4108

Tel: +61 1300 372 228

Fax: +61 7 3711 2328

CHINA

Shanghai ESAB A/P

Shanghai

Tel: +86 21 2326 3000

Fax: +86 21 6566 6622

INDIA

ESAB India Ltd

Calcutta

Tel: +91 33 478 45 17

Fax: +91 33 468 18 80

INDONESIA

P.T. ESABindo Pratama

Jakarta

Tel: +62 21 460 0188

Fax: +62 21 461 2929

JAPAN

ESAB Japan

Tokyo

Tel: +81 45 670 7073

Fax: +81 45 670 7001

MALAYSIA

ESAB (Malaysia) Snd Bhd

USJ

Tel: +603 8023 7835

Fax: +603 8023 0225

SINGAPORE

ESAB Asia/Pacific Pte Ltd

Singapore

Tel: +65 6861 43 22

Fax: +65 6861 31 95

SOUTH KOREA

ESAB SeAH Corporation

Kyungnam

Tel: +82 55 269 8170

Fax: +82 55 289 8864

UNITED ARAB EMIRATES

ESAB Middle East FZE

Dubai

Tel: +971 4 887 21 11

Fax: +971 4 887 22 63

Africa

EGYPT

ESAB Egypt

Dokki-Cairo

Tel: +20 2 390 96 69

Fax: +20 2 393 32 13

SOUTH AFRICA

ESAB Africa Welding & Cutting

Ltd

Durbanvill 7570 - Cape Town

Tel: +27 (0)21 975 8924

Distributors

For addresses and phone

numbers to our distributors in

other countries, please visit our

home page

www.esab.com

Содержание ES 300i

Страница 1: ...Instruction manual 0463 416 001 GB 20171016 Valid for serial no 721 742 xxx xxxx ET 300i ET 300iP Welding power source TIG 300 A...

Страница 2: ......

Страница 3: ...5 5 Connection of welding and return cables 18 5 6 Turning the mains power on off 18 5 7 Connect to cooler EC 1000 19 5 8 Fan control 19 5 9 Thermal protection 20 5 10 Voltage reducing device VRD 20 5...

Страница 4: ...E 32 7 1 Routine maintenance 32 7 2 Cleaning instruction 32 8 TROUBLESHOOTING 36 9 ERROR CODES 37 9 1 Error code descriptions 37 10 ORDERING SPARE PARTS 39 DIAGRAM 40 ORDERING NUMBERS 41 ACCESSORIES 4...

Страница 5: ...y precautions must meet the requirements that apply to this type of equipment The following recommendations should be observed in addition to the standard regulations that apply to the workplace All w...

Страница 6: ...ELECTRIC AND MAGNETIC FIELDS Can be dangerous to health Welders having pacemakers should consult their physician before welding EMF may interfere with some pacemakers Exposure to EMF may have other he...

Страница 7: ...uipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic...

Страница 8: ...es intended for TIG welding and for welding with covered electrodes MMA ESAB accessories for the product can be found in the ACCESSORIES chapter of this manual 2 2 Equipment The power source is suppli...

Страница 9: ...A 10 V 300 A 22 V 5 A 10 V 200 A 18 V Permissible load at MMA 40 duty cycle 300 A 32 0 V 60 duty cycle 250 A 30 0 V 100 duty cycle 200 A 28 0 V 200 A 28 0 V Permissible load at TIG 40 duty cycle 300 A...

Страница 10: ...inimum short circuit power on the network in accordance with IEC 61000 3 12 Duty cycle The duty cycle refers to the time as a percentage of a ten minute period that you can weld or cut at a certain lo...

Страница 11: ...oduct may cause radio interference It is the user s responsibility to take adequate precautions 4 1 Location Position the power source so that its cooling air inlets and outlets are not obstructed A M...

Страница 12: ...an or equal to Sscmin Refer to the technical data in the TECHNICAL DATA chapter The power source will automatically adjust to the supplied input voltage make sure it is protected by the correct fuse r...

Страница 13: ...g 1 5 2 Nm 13 3 17 7 in lb A 7 Use two cable ties to fasten the cables D 8 Optional If the fan with foam has been removed it shall now be re installed A symbol on the side of the fan G shows the air f...

Страница 14: ...4 INSTALLATION 0463 416 001 14 ESAB AB 2017 1 phase WARNING In 1 phase operation the terminal L3 is powered even though not connected Make sure to keep terminal L3 disconnected...

Страница 15: ...length 100 m 330 ft 100 m 330 ft 100 m 330 ft 100 m 330 ft 100 m 330 ft 100 m 330 ft Minimum recommended extension cord size 4 4 mm 4 4 mm 4 4 mm 4 4 mm 4 4 mm 3 6 mm NOTE Different variants of ET 300...

Страница 16: ...hieve 200 A in MMA and TIG mode MCB fuses break the circuit faster than porcelain fuses Supply from power generators The power source can be supplied from different types of generators However some ge...

Страница 17: ...ARNING Electric shock Do not touch the workpiece or the welding head during operation 5 2 Connections and control devices 1 User interface see chapter CONTROL PANEL 7 Gas supply input 2 Connection TIG...

Страница 18: ...or MMA welding the power source shall be supplemented with welding cable with electrode holder return cable with clamp 5 5 Connection of welding and return cables The power source has two outputs a po...

Страница 19: ...ce cable does not get squeezed between the power source and the cooling unit NOTE Power supply of the cooling unit is done from the welding power source via the connection cable for more information s...

Страница 20: ...trol is activated the control panel is locked for interaction but displays welding data 5 12 USB connection Always use the USB cover when the USB connection is not in use Do not use for charging units...

Страница 21: ...ection indicated by 8 to 10 Also used for access to hidden fuctions 5 Button to select 2 stroke or 4 stroke TIG only 12 Overheating indicator 6 Button to activate and deactivate remote control unit 13...

Страница 22: ...ue mode will result in automatically move to set current value mode The set indicator is off when measured values are shown 6 1 2 Weld program For each welding process MMA TIG three different weld pro...

Страница 23: ...hange between the parameters in the graph 6 Button to activate and deactivate remote control unit 17 Indicates which is shown in the display s seconds for gas pre flow gas post flow slope up and slope...

Страница 24: ...et parameter The set indicator 4 will be lit when a displayed value can be changed It cannot be changed from the panel when a remote control is activated Trying to change a value while in measured val...

Страница 25: ...X Gas pre flow time H 0 0 9 9 s 0 0 25 0 s 0 1 1 0 s H X Gas post flow time 0 0 25 0 s 0 1 7 0 s X X 2 stroke ON OFF ON X X 4 stroke ON OFF OFF X X Remote control unit ON OFF OFF X X Pulse ON OFF OFF...

Страница 26: ...display for welding current A is arithmetic average value Measured voltage Measured value in the display for arc voltage V is arithmetic average value 6 4 TIG functions explanation HF start The HF st...

Страница 27: ...e trigger switch 2 to slope up the current to the set current value To stop the welding press the trigger switch again 3 The current will slope down to the pilot level again Release the trigger switch...

Страница 28: ...y be 10 Pulse frequency The amount of pulse cycles in a time period The higher the frequency the more pulse cycles per time period When the pulse frequency is set low the weld pool will have time to p...

Страница 29: ...s the trigger switch again 3 The current will slope down to the pilot level again Release the trigger switch 4 to terminate the arc The shielding gas will continue to flow in order to protect the weld...

Страница 30: ...nnot be changed while welding H Hidden function 6 5 1 Hidden MMA functions There are hidden functions in the control panel To access the functions press parameter selection button for 3 seconds see se...

Страница 31: ...urrent changes in response to variations in arc length during welding Use a low value of arc force to get a calm arc with little spatter and use a high value to get a hot and digging arc Arc force onl...

Страница 32: ...e more often during severe dusty conditions Before each use make sure that Product and cables are not damaged The torch is clean and not damaged 7 1 Routine maintenance Maintenance schedule during nor...

Страница 33: ...source from the mains supply WARNING Wait at least 30 seconds for the capacitors to discharge before continuing 2 Remove the four screws holding the right side panel R and remove the panel 3 Clean th...

Страница 34: ...s no dust left on any part of the power source 7 After having finished cleaning the power source reattach the power source panels in the reverse order NOTE When reattaching the right side panel make s...

Страница 35: ...7 MAINTENANCE 0463 416 001 35 ESAB AB 2017 8 Tighten the screws on the side panels with 3 Nm 0 3 Nm 26 6 in lb 2 6...

Страница 36: ...shielding gas gas flow welding current filler rod placement electrode diameter and welding mode on power source is used Make sure the gas valve on the TIG torch is on No arc Check that display is on t...

Страница 37: ...re is sufficient coolant fluid in the cooler The error code will automatically disappear when the coolant has cooled down and is ready for use again If the error persists contact a service technician...

Страница 38: ...wer source If the error persists contact a service technician Err 8 Water cooling disabled The hose from the torch is not connected to the cooling unit Action If a water cooled torch is used make sure...

Страница 39: ...N 60974 10 Canadian standards CAN CSA E60974 1 and US standards ANSI IEC 60974 1 On completion of service or repair work it is the responsibility of the person s performing the work to ensure that the...

Страница 40: ...DIAGRAM 0463 416 001 40 ESAB AB 2017 DIAGRAM...

Страница 41: ...RS Ordering number Denomination Type Notes 0445 100 900 Welding power source ET 300i EU 0445 100 920 Welding power source ET 300iP EU 0463 423 001 Spare parts list 0463 424 001 Service manual Technica...

Страница 42: ...00 565 0700 300 567 TIG torch TXH 401w 4 m 13 ft TIG torch TXH 401w 8 m 26 ft 0445 045 880 EC 1000 Cooler 0460 330 881 Trolley 0445 197 880 Shoulder strap kit 0700 006 902 Welding cable kit 3 meter in...

Страница 43: ...2 Interconnection cable 6 pin 5 m 16 4 ft Interconnection cable 6 pin 10 m 32 8 ft Interconnection cable 6 pin 25 m 82 ft 0445 550 881 ER 1 F Foot pedal 5 m 16 4 ft interconnection cable 6 pin include...

Страница 44: ...Henares MADRID Tel 34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB International AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWI...

Отзывы: