background image

ESAB EMS215IC/EMP215IC

Manual 0463 413 001 

ROUTINE MAINTENANCE  

7-1   

7 MAINTENANCE

 

NOTE!

Regular maintenance is important for safe, reliable operation

!

CAUTION

Only persons with the appropriate electrical knowledge (authorized personnel) may 
remove the cover of the product to connect or carry out service, maintenance or repair 
work on the welding equipment.

!

CAUTION

The product is covered by manufacturer’s warranty. Any attempt to carry out repair work 
by non-authorized service centers will invalidate the warranty.

WARNING

Disconnect power before performing maintenance!

 

NOTE!

Perform maintenance more often during severe dusty conditions.

Before each use - make sure that:

•  The torch body and torch cable and leads are not damaged.
•  The contact tip on the torch is not damaged.
•  The nozzle on the torch is clean and does not contain any debris.

7.01  Routine Maintenance

Maintenance schedule during normal conditions.

Interval

Area to maintain

Every 3 month

Clean or replace 

unreadable labels.

Clean weld 

terminals.

Check or replace weld cables.

Every 6 month

Clean inside 

equipment.

Содержание EMP 215ic

Страница 1: ...Revision AA Issue Date December 20 2016 Manual No 0463 413 001 esab com ESAB EMP 215IC EMS 215IC MULTI PROCESS WELDER Service Manual...

Страница 2: ...take the time to read the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY The Brand...

Страница 3: ...13 001 Published by ESAB Group Inc 2800 Airport Rd Denton Texas 76207 www esab com Copyright 2016 by ESAB All rights reserved Reproduction of this work in whole or in part without written permission o...

Страница 4: ...ereof contained in this manual and accompanying labels and or inserts when installed operated maintained and repaired in accordance with the instructions provided This equipment must be checked period...

Страница 5: ...77 G teborg Sweden Phone 46 31 50 90 00 Fax 46 584 411 924 The following harmonised standard in force within the EEA has been used in the design EN 60974 1 2012 Arc Welding Equipment Part 1 Welding P...

Страница 6: ...ESAB EMS215C EMP215C 6 DECLARATION OF CONFORMITY Manual 0463 413 001 This Page Intentionally Blank...

Страница 7: ...re Rollers 3 7 3 08 Shielding Gas 3 8 3 09 Volt Ampere Curves 3 8 3 10 Duty Cycle 3 10 3 11 Control Panel 3 11 4 SERVICE INSTRUCTIONS 4 1 4 01 What is ESD 4 1 5 POWER SUPPLY INTRODUCTION 5 1 5 01 Intr...

Страница 8: ...ire Feeder Replacement Parts CSA Systems 8 6 8 07 Wire Feeder Replacement Parts CE Systems 8 7 9 DISASSEMBLY 9 1 9 01 Safety Precautions for Disassembly 9 1 9 02 User Interface TFT Display Assembly Re...

Страница 9: ...l electrical hazards which could result in personal injury or loss of life CAUTION CAUTION Means hazards which could result in minor personal injury WARNING Read and understand the instruction manual...

Страница 10: ...r personnel from arc rays and hot sparks with a suitable non flammable partition or curtains 7 Use goggles over safety glasses when chipping slag or grinding Chipped slag may be hot and can fly far By...

Страница 11: ...uses localized Electric and Magnetic Fields EMF Welding and cutting current creates EMF around welding cables and welding machines Therefore 1 Welders having pacemakers should consult their physician...

Страница 12: ...trucks undercarriages benches wall post or racks Never secure cylinders to work tables or fixtures where they may become part of an electrical circuit 4 When not in use keep cylinder valves closed Ha...

Страница 13: ...sition and in good repair 6 Use equipment only for its intended purpose Do not modify it in any manner CAUTION ADDITIONAL SAFETY INFORMATION For more information on safe practices for electric arc wel...

Страница 14: ...ment 3 The workplace must be suitable for the purpose be free from drafts 4 Personal safety equipment Always wear recommended personal safety equipment such as safety glasses flame proof clothing safe...

Страница 15: ...use fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing Protect your ears Use earmuffs or other hearing protection MALFUNCTION Call for exp...

Страница 16: ...ESAB EMS215C EMP215C 1 8 SAFETY INSTRUCTIONS Manual 0463 413 001 This Page Intentionally Blank...

Страница 17: ...In a domestic environ ment this product may cause radio interference It is the user s responsibility to take adequate precautions 2 02 Lifting Instructions The Power Supply includes a series of handl...

Страница 18: ...source must be Correctly installed if necessary by a qualified electrician Correctly earthed electrically in accordance with local regulations Connected to the correct size power point and fuse as tab...

Страница 19: ...ker 110 A 19 5 V 40 duty cycle 150A 21 5 V 15A Breaker 100 A 19 V 25 duty cycle 205 A 24 25 V 20 duty cycle 20A Breaker 130 A 20 5 V Setting range DC 15 A 14 75 V 235 A 26 V 15 A 14 75 V 130 A 20 5 V...

Страница 20: ...le 20 A Breaker 130 A 20 5 V Setting range DC 15 A 14 75 V 220 A 26 V 15 A 14 75 V 130 A 21 V Permissible load at SMAW Stick 100 duty cycle 100 A 24 V 65 A 22 6 V 60 duty cycle 125 A 25 V 80 A 23 2 V...

Страница 21: ...0 60Hz single phase supply Supply voltage 230V AC 120V AC Input current at maximum output 30 Amps 30 Amps Maximum recommended fuse or circuit breaker rating Time delay fuse UL class RK5 Refer to UL 24...

Страница 22: ...ESAB EMS215C EMP215C 2 6 INSTALLATION Manual 0463 413 001 208 230V 50A 120V 15A 120V 20A NEMA 6 50P 230VAC plug...

Страница 23: ...andle Never pull on the cables WARNING Rotating parts can cause injury take great care WARNING Electric shock Do not touch the workpiece or the welding head during opera tion Icon Reference Guide Home...

Страница 24: ...ngth is shortened to reduce or eliminate the freezing of the stick electrode in the weld puddle Trim bar Changing the weld bead profile from flat to convex or flat to concave Downslope Sloping the cur...

Страница 25: ...e beginning of the weld cycle Bead profile concave Volts Bead profile convex Wire feed speed Wire diameter V 8 mm 030 Inductance The addition of inductance into the arc characteristics to stabilize th...

Страница 26: ...nt or wire feed speed selection 2 Display 3 Knob for voltage selection 4 Main knob for menu navigation 5 Torch Remote control connection 6 Negative output 7 Polarity changeover cable and receptacle co...

Страница 27: ...ease refer to electrode packaging for information relating to the correct electrode polarity Connect the work lead to the remaining welding terminal on the power source Secure the work lead s contact...

Страница 28: ...through the inlet guide 3 between the rollers through the outlet guide and into the MIG torch 5 Re secure the pressure roller arm and wire drive tension screw and adjust the pressure accordingly Remov...

Страница 29: ...torch approximately 2 50 mm from the piece of wood the wire should be fed out and bend illustration B 3 07 Changing the Feed Pressure Rollers A dual groove feed roller is supplied as standard It can...

Страница 30: ...mixed gas Ar CO2 or Trimix He Ar CO2 Aluminium and silicon bronze use pure argon gas Ar In the sMIG mode see section sMIG mode in the CONTROL PANEL chapter the optimal welding arc with the gas you use...

Страница 31: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 OPERATION 3 9...

Страница 32: ...and welding current can be selected Use the graphs below to determine the correct duty cycle for a given welding current 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 110 120 130...

Страница 33: ...are similar If a welding process has a blue indication then a remote trigger devise needs to be used when that process is selected If the process has Red Orange color then it will be live hot as soon...

Страница 34: ...3 Material thickness 4 Wire feed speed 5 Voltage trim 6 Dialogue box 7 Weld bead shape Must be in Advanced Settings 1 2 3 4 5 6 7 NOTE When a parameter setting is being changed the background and tex...

Страница 35: ...on 3 Wire feed speed 4 Voltage 5 Dialogue box 1 2 3 4 5 3 11 6 Stick mode SMAW EMP 215ic only 1 Home screen 2 Information 3 Amperage 4 Voltage OCV or arc 6 Dialogue box 1 2 3 5 6 5 Stick mode ON OFF 4...

Страница 36: ...11 8 Settings 1 Language 2 Inch Metric 3 Basic Advanced 4 Reset mode 5 Information 6 Dialog box Home screen 7 1 2 3 4 5 6 7 3 11 9 User Manual Information 1 Operation information 2 Maintenance inform...

Страница 37: ...age ESD damage can be prevented by awareness If static electricity is prevented from building up on you or on anything at your work station then there cannot be any static discharges Nonconductive mat...

Страница 38: ...ESAB EMS215IC EMP215IC 4 2 SERVICE INSTRUCTIONS Manual 0463 413 001 This Page Intentionally Blank...

Страница 39: ...ection auxiliary power supply full bridge inverter main transformer secondary inductor and secondary diode modules Control module The control board with a microprocessor that monitors and controls the...

Страница 40: ...R BR1 BR2 BOOST PFC INVERTER Q3 Q4 Q6 Q7 INDUCTOR L1 POWER BOARD PCB2 15AP1 INTERNAL POWERSUPPLY CIRCUIT BREAKER ON OFF SWITCH CB1 SW1 120Vac 230Vac 10 50 60Hz FERRITE RINGS L3 L4 L5 L6 DMA SECONDARY...

Страница 41: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 3 This Page Intentionally Blank...

Страница 42: ...ESAB EMS215IC EMP215IC 5 4 POWER SUPPLY INTRODUCTION Manual 0463 413 001 A 12892_AA 5 04 System Schematic for CSA Systems...

Страница 43: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 5 A 12892_AA...

Страница 44: ...ESAB EMS215IC EMP215IC 5 6 POWER SUPPLY INTRODUCTION Manual 0463 413 001 5 05 System Schematic for CE Systems A 13146_AA...

Страница 45: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 POWER SUPPLY INTRODUCTION 5 7 A 13146_AA...

Страница 46: ...7 8 9 10 7 11 Item Description Designator 1 Control PCB PCB 20AP1 2 Circuit Breaker CB1 3 On Off Switch SW 1 4 Fan 1 and Fan 2 M1 and M2 5 PFC Inductor L1 6 Output Diode PCB PCB4 7 Main Transformer T...

Страница 47: ...pcb CN5 CN6 CN7 CN8 Check Optical sensor power pcb U12 Operate the system at the specified duty cycle 2 Err 002 Warning TEMPERA TURE FAULT Output diode Temperature fault Analog tempera ture sensor UI...

Страница 48: ...y resets and this was not confirmed by the system Possible software bug or communication protocol error UI Display CN8 Ctrl PCB Should not experience this error in the field Causes are poor communi ca...

Страница 49: ...ower ON If fails 2 times reading from valid sector 1 15 then Display this for 3 sec UI Display Check if the SPI IC gone bad Console errors 1 N A N A Flash CRC Error Internal to U15 MCU processor the b...

Страница 50: ...Q7 Collector Q6 Collector Q3 Collector D49 D50 Cathode Q19 Collector A series of quick checks can be done to verify Main Power components are not shorted Remove the right side panel to access this are...

Страница 51: ...ow a reading other than as indicated above then the ten components will have to be checked to identify the failed component s The following images show the previous steps listed In the oval you will s...

Страница 52: ...all three leads b Check for short between Line 1 and Line 2 c Check for short between both Line 1 and Line 2 leads to GROUND lead Replace MAINS POWER CABLE PLUG if fault is found The following image s...

Страница 53: ...e oval you will see the step number and below that the meter reading you should see 2b ON Shorted OFF Open 2c Open Infinity 2b ON Shorted OFF Open 2c Open Infinity 3 CB1 CIRCUIT BREAKER a If breaker i...

Страница 54: ...iode Check on both Bridge rectifiers If either one has open or shorted diode replace both BR1 BR2 The following image shows the previous step listed In the oval you will see the step number and below...

Страница 55: ...e continuity between BR1 or BR2 Positive Terminals and BUS terminals on POWER PCB2 for 23 ohms If open or shorted replace POWER PCB2 The following image shows the previous step listed In the oval you...

Страница 56: ...d on BR2 terminal for forward biased diode 0 30 00 7VDC If open or shorted replace POWER PCB2 See following illustration 9 C35 38 Disconnect wire from POWER PCB2 from PFC terminal a With meter in resi...

Страница 57: ...iode reading between Heatsink Terminals Q7 and BR2 terminal d With meter in diode setting check for diode reading between Heatsink Terminal Q6 and either end of R88 or R89 on Power PCB2 If open or sho...

Страница 58: ...ad on WELD OUT PUT terminal check for forward biased diode drop reading 2 With positive meter lead on OUTPUT WELD terminal and with negative meter lead on WELD OUTPUT terminal check for reverse biased...

Страница 59: ...04 Initial Power Up Test Using Generators or Extension cords If a problem is encountered while running on a generator or while using an extension cord note the problem and then plug the unit directly...

Страница 60: ...D44 UI COM Flashing D45 uP OK ON D85 10 3_VB OK ON D86 5V_10 OK ON D87 MIG SOL ON OFF D88 TRIGGER ON OFF D89 TIG SOL OFF D90 FAN ON OFF If the unit does not perform as indicated proceed to subsection...

Страница 61: ...D40 24V_1 LOW OFF D43 BUS V ERR OFF D44 UI COM ON D45 uP OK ON D85 10 3_VB OK ON D86 5V_10 OK ON D88 TRIGGER ON OFF D89 TIG SOL OFF D90 FAN ON OFF 1 Use EN3 ENCODER to select GTAW LIFT TIG process 2...

Страница 62: ...RR OFF D44 UI COM ON D45 uP OK ON D85 10 3_VB OK ON D86 5V_10 OK ON D87 MIG SOL ON OFF D88 TRIGGER ON OFF D89 TIG SOL OFF D90 FAN ON OFF 1 With gun in position activate MIG gun trigger On CONTROL PCB3...

Страница 63: ...lem Open fuse tripped breaker Measure voltage at mains outlet b Defective MAINS POWER CABLE PLUG Measure voltage to SW1 Replace if defective c Defective SW1 ON OFF SWITCH Measure voltage from SW1 Repl...

Страница 64: ...for the PFC Transistor the other on the heatsink for the switching transistors Q3 4 6 7 The Third is located on the Main Transformer T1 The forth is on the heatsink on the OUTPUT DIODE PCB4 When thes...

Страница 65: ...413 001 TROUBLESHOOTING 6 19 The following image shows the previous steps 4a and 4b listed In the oval you will see the step number and below that the meter reading you should see 4a Approximately 12...

Страница 66: ...5VDC If both of these measurements are correct replace CONTROL PCB3 d Defective POWER PCB2 1 On the CONTROL PCB3 Connector CN17 Measure from pin 6 to pin 4 The voltage should be approx 1 8VDC If volta...

Страница 67: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 TROUBLESHOOTING 6 21 4c 1 Approximately 1 8VDC 4c 2 0 25 VDC CN17 CN19 3 4 6 3 4 6 4d 1 Approximately 1 8VDC 4d 2 0 25 VDC...

Страница 68: ...PCB Test see subsection 6 06 b Defective CS1 Current Sensor Perform CS 1 Test see subsection 6 06 c Defective CONTROL PCB3 d Defective USER INTERFACE PCB1 5 ERROR MESSAGE VOLTAGE FEEDBACK FAULT a Open...

Страница 69: ...on b Control PCB3 Check that LED D87 turns on when trigger is activated If it is not on replace PCB3 c Defective GS1 GAS SOLENOID Gas valve supply voltage is 24vdc but if you measure it with true RMS...

Страница 70: ...UBLESHOOTING Manual 0463 413 001 The following image shows the previous steps 2c 3a and 3b listed In the oval you will see the step number and below that the meter reading you should see CN10 2c 5 VDC...

Страница 71: ...18VDC_PRI OK ON 3 Measure for 400VDC buss voltage between terminals LINE to LINE If problem is found remove power disconnect the harness connectors from CONTROL PCB3 connectors CN1 CN2 and CN4 Retest...

Страница 72: ...1 Connector CN10 ENCODER PCB6 to PCB1 Connector CN11 ENCODER PCB7 to PCB1 Connector CN12 1 For the ENCODER PCB under test disconnect the harness connector from PCB1 At the mating con nector at PCB1 me...

Страница 73: ...ce OUTPUT DIODE PCB4 The following image shows the previous steps listed In the oval you will see the step number and below that the meter reading you should see 2 0 3 0 7 VDC 3 Open Infinity CURRENT...

Страница 74: ...G Manual 0463 413 001 The following image shows the previous steps listed In the oval you will see the step number and below that the meter reading you should see 4c 1 0 5VDC 100A with load 4c 2 0 0 V...

Страница 75: ...e sockets are damaged or retracted into the connector body preventing a good electrical connection a If LED D88 does turn on and no arc will ignite in GTAW process when the torch electrode is touched...

Страница 76: ...63 413 001 Control PCB D90 FAN ON D86 5V_1 OK D35 PS_OK D88 TRIGGER D40 24V_1 LOW D43 BUSS V ERROR D44 UI COM D45 P OK D33 PWM D89 TIG SOL ON D87 MIG SOL ON D85 10 3_VB OK R642 WIRE FEED SPEED CALIBRA...

Страница 77: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 TROUBLESHOOTING 6 31 Main PCB D42 24V_SEC OK D53 18V_PRI OK PFC Bus R89 R88 TRANSF2 TRANSF1 Line 1 Line 2 Line Line CN2 CN4 CN1 CN8 CN7 CN9 Output Diode PCB...

Страница 78: ...ESAB EMS215IC EMP215IC 6 32 TROUBLESHOOTING Manual 0463 413 001 This Page Intentionally Blank...

Страница 79: ...out repair work by non authorized service centers will invalidate the warranty WARNING Disconnect power before performing maintenance NOTE Perform maintenance more often during severe dusty conditions...

Страница 80: ...outlet 5 Inspect if the inlet wire guide 4 outlet wire outlet 2 or the feeder roller 3 are worn and need replace ment See appendix WEAR PARTS for ordering numbers of parts 6 Remove and clean the feede...

Страница 81: ...CEMENT PARTS 8 01 Introduction System Replacement numbers Ordering no Model Note 0558 102 239 EM 215ic Wire Reel Size 4 8 100 200 mm CSA Bayonet 0558 102 240 EMP 215ic Wire Reel Size 4 8 100 200 mm CS...

Страница 82: ...Hinge 4 1 Nut M4 0 7 mm 5 1 0558 102 407 Hinge pin 6 1 0558 102 398 Side frame Left 7 1 Nut M6 1 mm 8 1 0558 102 399 Handle 9 2 0558 102 400 Top handle 10 1 0558 102 397 Side frame right 11 4 Screw M6...

Страница 83: ...8 1 0558 102 437 Lens assembly kit 9 2 0558 102 438 Lens bezel Including decal 10 1 0558 102 440 Small knob 11 1 0558 102 441 Large knob 12 1 0558 102 418 50mm female Dinse 13 1 0558 102 419 Polarity...

Страница 84: ...8 102 437 Lens assembly kit 9 2 0558 102 438 Lens bezel Including decal 10 1 0558 102 440 Small knob 11 1 0558 102 441 Large knob 12 1 0558 102 418 50mm female Dinse 13 1 0558 102 419 Polarity changeo...

Страница 85: ...n Notes 1 1 0558 102 416 Circuit Breaker CB1 2 1 0558 102 415 ON OFF Switch SW1 3 1 0558 102 427 Control PCB PCB3 20AP1 4 1 0558 102 426 Power PCB Assembly PCB2 15AP1 5 1 0558 102 420 Fan 1 2 M1 M2 EV...

Страница 86: ...guide MS SS Flux Cored 0 024 0 6 mm 2 0558 102 328 Wire inlet guide MS SS Flux Cored 0 024 0 030 0 035 0 045 0 6 mm 0 8 mm 0 9 mm 1 2 mm 3 0558 102 334 Key drive shaft N A N A 4 7977036 Feed roll V gr...

Страница 87: ...Cored 0 6 mm 0 8 mm 0 9 mm 1 2 mm 0 023 0 030 0 035 0 045 3 0558 102 457 Key drive shaft N A N A 4 0367 556 001 Feed roll V groove Fe SS Flux Cored 0 6 mm 0 8 mm 0 023 0 030 0367 556 002 Feed roll V...

Страница 88: ...ESAB EMS215IC EMP215IC 8 8 REPLACEMENT PARTS Manual 0463 413 001 This Page Intentionally Blank...

Страница 89: ...t is on Wait 40 seconds after removing power before handling 9 02 User Interface TFT Display Assembly Removal Read and follow safety information in Section 1 before proceeding with disassembly Follow...

Страница 90: ...e Control PCB Not shown 3 Remove the four 4 screws on the inside of the unit that secure the User Interface TFT Display in place You will need to access these from both sides of the unit 4 4 Remove th...

Страница 91: ...rcuit Board Unplug the unit before beginning disassembly procedure 1 Remove eight 8 screws securing the power side cover and frame to the power supply 8 2 Take photos or notes on all the harness conne...

Страница 92: ...ormer and PFC Inductor connections along the bottom of the Power PCB Assembly 3 Disconnect each of these from the Power PCB Assembly Not shown CAUTION Keep these 4 screws connecting the wires from alo...

Страница 93: ...IFIER BR1 BR2 BOOST PFC INVERTER Q3 Q4 Q6 Q7 INDUCTOR L1 POWER BOARD PCB2 15AP1 INTERNAL POWERSUPPLY CIRCUIT BREAKER ON OFF SWITCH CB1 SW1 120Vac 230Vac 10 50 60Hz FERRITE RINGS L3 L4 L5 L6 DMA SECOND...

Страница 94: ...ESAB EMS215IC EMP215IC A 2 APPENDIX Manual 0463 413 001 APPENDIX 2 CSA SYSTEM SCHEMATIC 115 230V UNITS A 12892_AA...

Страница 95: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 3 A 12892_AA...

Страница 96: ...ESAB EMS215IC EMP215IC A 4 APPENDIX Manual 0463 413 001 APPENDIX 3 CE SYSTEM SCHEMATIC 115 230V UNITS A 13146_AA...

Страница 97: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 5 A 13146_AA...

Страница 98: ...clamp on ammeter read the actual output amperage on the positive output cable Adjust Trimpot R34 on the Control PCB3 until the measured output amperage on the clamp on meter reads 180A 3A 0A Next set...

Страница 99: ...ESAB EMS215IC EMP215IC Manual 0463 413 001 APPENDIX A 7 This Page Intentionally Blank...

Страница 100: ...ESAB EMS215IC EMP215IC A 8 APPENDIX Manual 0463 413 001 Revision History Date Rev Description Dec 20 2016 AA Manual release...

Страница 101: ...This Page Intentionally Blank...

Страница 102: ...1 50 95 00 Fax 46 31 50 92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 UKRAINE ESAB Ukraine LLC Kiev Te...

Отзывы: